Both the power cable and the release cable shall come out from the tube on the opposite side of the crown. The release cable shall be aligned with the
motor as much as possible.
As to the fitting of the manual release system, follow the instructions given in paragraph 7
Check if a suitable differential switch is present upstream of the system, as prescribed by the current standards and provide a thermo-magnetic switch
with omnipolar breaking and an opening distance of at least 3mm on the power supply mains.
Before connecting the operator, make sure that the system is not supplied with power.
For the operator connection refer to the figure below.
At the end of the electric connection, supply the operator with power and check the direction of rotation. If it does not correspond to the desired direction
of rotation, disconnect the power supply and exchange the brown with the black wires of the motor cable.
a
b
c
3. Cable routing
4. Electric connection diagram
Example of a key selector connection.
230V~ 50Hz
Yellow / green
Brown
Blue
Black
Motor side
Power supply
5. Rolling shutter fastening
Allow a min. bending radius of 150mm in order to avoid the block of