OPERaTING INsTRUCTIONs
analog Timer
The "Time Off" setting determines the interval between cycles from
0.5 - 45 minutes. The "Time On" setting determines the actual time the
compressor drains condensate from the 1/4" or 1/2" condensate outlet port,
between 0.5 - 10 seconds. The timer's cycle rate and drain opening time
should be adjusted to open just enough to discharge the condensate. The
timer is properly set when it opens and discharges all condensate and then
vents air for approximately one second before closing. Adjustments may
be made depending on many factors, including humidity and duty cycle.
(See Figure 6)
Solenoid Valve
energized (LED)
Test Button
(OPEN)
Figure 6 – analog

Digital Timer

When indicator is lit, timer is in ON (drain) state.
On
Off
Mode
Figure 7 – Digital
8
Adjustment
on period
(ON/OPEN)
Add
Enter
Solenoid Valve
de-energized (LED)
Adjustment
off period
(OFF/CLOSED)
Reset