°C/°F:
Switching the temperature display from °C to °F, and vice versa.
Window:
Setting a temperature window (only with control units with optical coupler
output). If the actual temperature is within the temperature window, a
potential-free contact (optical coupler output) will be switched through.
Cal:
Re-adjustment of the soldering station (WCB 2 only).
PC interface:
RS232 (WCB 2 only).
Temp. gauge:
Integrated temperature gauge for thermal element Type K (WCB 2 only).
Hot Air Soldering Tool
The hot air nozzles are screwed into the heater element. To change the nozzle use the 8 AF
socket spanner and lock the heater element with an open ended spanner.
Important: The maximum thread depth is 5 mm (0.2"). A longer thread will irreparably damage
the heater element.
Nitrogen N
reduces oxidation and flux remains active for longer. We recommend the nitrogen
2
N
that is available in steel bottles. The bottle must be equipped with a 0-10 bar pressure
2
reducer.
Soldering Iron
The transition between the heater element/sensor and the soldering iron bit must not be
degraded by dirt, foreign bodies or damage because these will have an effect on the precision
of temperature regulation.
When heating up for the first time, wet the selectively tinnable soldering iron bit with solder.
This removes oxide layers and soiling that have formed during storage. Always ensure that
the soldering iron bit is well tinned during breaks in soldering and when placing in the holder.
Do not use aggressive fluxes.
Important: Always ensure that the soldering iron bit is correctly seated.
The soldering equipment has been set up for a medium size bit or nozzle. Variations may
occur if the bit is changed or if other bit shapes are used.
WAD_100
27

5. Safety instructions

The manufacturer assumes no liability for uses other than those described in the operating
instructions, or for unauthorized alterations.
These operating instructions and warnings should be read carefully and kept in an easily
visible location in the vicinity of the soldering iron. Non-observance of these warnings can
result in accidents, injury or risks to health.
The WELLER soldering station WAD 100 is in compliance with the EC Declaration of Conformity
in accordance with the basic safety requirements specified by Directives 89/336/EEC and
73/23/EEC.

6. Accessories

5 33 114 99
Hot air set HAP 1
5 29 161 99
Soldering iron set WSP 80
5 33 110 99
Soldering iron set MPR 30
5 33 111 99
Soldering iron set MLR 21
5 33 112 99
Soldering iron set LR 21, antistatic
5 33 113 99
Soldering iron set LR 82
5 33 133 99
Soldering iron set WTA 50
5 13 050 99
Reflow soldering unit EXIN 5
5 27 028 99
Preheating plate WHP 80
5 25 030 99
Thermal insulating unit WST 20
5 31 181 99
External input unit WCB 1
5 31 180 99
External input unit WCB 2

7. Scope of supply

WAD 100
PUD 100
Control Unit
Control Unit
Hot Air Soldering Tool
Operating Instructions
Holder
3.5 mm Jack Plug
Service Set
Mains Cable
Operating Instructions
3.5 mm Jack Plug
22.02.2002, 15:48 Uhr