Electrical connection
The mains power supply must correspond to the rating
indicated on the plate situated inside the hood. If provided with
a plug connect the hood to a socket in compliance with current
regulations and positioned in an accessible area. If it not fitted
with a plug (direct mains connection) or if the plug is not
located in an accessible area apply a bi-polar switch in
accordance with standards which assures the complete
disconnection of the mains under conditions relating to over-
current category III, in accordance with installation
instructions.
Warning: Before re-connecting the hood circuit to the mains
supply and checking the efficient function, always check that
the mains cable is correctly assembled.
Mounting
Before beginning installation:
•
Check that the product purchased is of a suitable size for
the chosen installation area.
•
To facilitate installation, remove the fat filters and the
other parts allowed and described here, dismantle and
mount it.
To remove see also the relative paragraphs.
•
Remove the active carbon (*) filter/s if supplied (see also
relative paragraph). This/these is/are to be mounted only
if you want lo use the hood in the filtering version.
•
Check (for transport reasons) that there is no other
supplied material inside the hood (e.g. packets with
screws (*), guarantees (*), etc.), eventually removing
them and keeping them.
•
If possible, disconnect and move freestanding or slide-in
range from cabinet opening to provide easier access to
rear wall/ceiling. Otherwise put a thick, protective
covering over countertop, cooktop or range to protect
from damage and debris. Select a flat surface for
assembling the unit. Cover that surface with a protective
covering and place all canopy hood parts and hardware
in it.
•
Disconnect the hood during electrical connection, by
turning the home mains switch off.
•
In addition check whether near the installation area of the
hood (in the area accessible also with the hood mounted)
an electric socket is available and it is possible to
connect a fumes discharge device to the outside (only
suction version).
•
Carry out all the masonry work necessary (e.g.
installation of an electric socket and/or a hole for the
passage of the discharge tube).
Expansion wall plugs are provided to secure the hood to most
types of walls/ceilings. However, a qualified technician must
verify suitability of the materials in accordance with the type of
wall/ceiling. The wall/ceiling must be strong enough to take
the weight of the hood. Do not tile, grout or silicone this
appliance to the wall. Surface mounting only.
Attention! The chimney is predisposed for installation of
the filter Version.
In certain models where it is required to use the cooker hood
in the suction version then it is possible to overturn the upper
section of the chimney
and insert it inside the lower section of the chimney so that the
air-exit perforations are not visible.
The chimneys in which this operation is possible are
recognizable by their bracket fixing points G which are
repeated also in the lower side of the upper section of the
chimney.
Installation wall model
Fig. 5
1.
Using a pencil, draw a line on the wall, extending up to
the ceiling, to mark the centre.
installation.
2.
Rest the drilling template against the wall: the vertical
centre line printed on the drilling template must
correspond to the centre line drawn on the wall, and the
bottom edge of the drilling template must correspond to
the bottom edge of the hood.
3.
Place the lower support bracket on the perforation
diagram making it coincide with the traced triangle, mark
the two external holes and perforate.
perforation diagram, insert two wall-dowels and fix the
support bracket of the hood with two 5x45 mm screws.
4.
Hang the hood onto the lower bracket.
5.
Adjust the distance of the hood from the wall.
6.
Adjust the horizontal position of the hood.
7.
Using a pencil mark the cooker hood permanent drill hole
inside the suction group (2 fixing points are necessary for
permanent mounting).
8.
Remove the hood from the lower bracket.
9.
Drill at the point marked (Ø8mm).
10. Insert 2 wall screw anchors.
11. Apply the flues support bracket G to the wall adherent to
the ceiling, use the flues support bracket as a perforation
diagram (if present, the small slot on the support must
coincide with the line drawn previously on the wall) and
mark two holes with a pencil. Make the holes (Ø8mm),
and insert 2 dowels.
12. Fix the chimney support bracket to the wall using two
5x45mm screws.
13. Hook the hood onto the bottom bracket.
14. Fix the hood into its final position on the wall
(ABSOLUTELY ESSENTIAL).
15. Connect a pipe (pipe and pipe clamps not provided, to be
purchased separately) for discharge of fumes to the
connection ring located over the suction motor unit.
If the hood is to be used in ducting version, the other end
of the pipe must be connected to a device expelling the
fumes to the outside. If the hood is to be used in filter
version, then fix the deflector F to the chimney support
bracket G and connect the other extremity of the pipe to
the connection ring placed on the deflector F.
16. Connect the electricity.
17. Insert the flue into its housing over the hood to cover the
suction unit completely.
15
This will facilitate
Remove the