30" ELECTRIC RANGE INSTALLATION INSTRUCTIONS
Three Conductor Wire Connection to Range
If local codes permit connection of the frame grounding
conductor to the neutral wire of the copper power supply cord
(see Figure 3):
1. Remove the screws from the access plate at the lower right
end of the rear cover to expose range terminal connection
block.
2. Using the nuts supplied in the literature package, connect
the neutral of the copper power supply cord to the center
silver-colored terminal of the terminal block, and connect
the other wires to the outer terminals. Match wires and
terminals by color (red wires connected to the right
terminal, black wires connected to the left terminal) (see
figure 3).
3. Replace the terminal cover and replace the screws.
Terminal
Block
Black
Wire
A User Supplied
Strain-relief Must
Be Installed at This
Location.
Silver Colored Terminal
Cord
Mounting
Plate
Neutral
(White Wire)
Grounding
Strap
1 1/8" (2.9 cm) Dia.
Direct Connection
Hole. Punch Out
To 240 V
Knockout for 1 3/8"
Receptacle
(3.5 cm) Dia. Cord
Kit Hole.
Figure 3
Four Conductor Wire Connection to Range
Where local codes does NOT permit connection of the frame
grounding conductor to the neutral wire of the copper power
supply cord (see Figure 4):
1. Remove the screws from the access plate at the lower right
end of the rear cover to expose range terminal connection
block.
2. Remove the grounding strap from the terminal block and
from the appliance frame.
3. Using the nuts supplied with the literature package,
connect the ground wire (green) of the copper power
supply cord to the frame of the appliance with the ground
screw, using the hole in the frame where the ground strap
was removed (see Figure 4).
4. Connect the neutral of the copper power supply cord to
the center silver-colored terminal of the terminal block,
and connect the other wires to the outer terminals. Match
wires and terminals by color (red wires connected to the
right terminal, black wires connected to the left terminal).
Red Wire
5. Replace the terminal cover and replace the screws.
Terminal Block
Black Wire
1 1/8" (2.9cm)
Dia. Direct
Connection
Hole. Punch
Out Knockout
for 1 3/8"
(3.5cm) Dia.
Cord Kit Hole.
A User Supplied
Strain-relief Must
Be Installed at This
Location
NOTE: Be sure to remove the
supplied grounding strap.
3
Silver Colored Terminal
Neutral
(White Wire)
Ground (Bare
Copper Wire)
To 240 V Receptacle
Figure 4
Red
Wire