7. Advanced parameter settings
First, carry out the basic settings (chapters 8, 9 and 10), before changing the
advanced parameter settings.
Press the "M & +" keys simultaneously in the switched off state to access the
parameter setting. You can access the respective parameters (01-07) using the "M
key". If you want to adjust the setting, you can do so using "+" and "-".
Number
Temperature calibration
1
Used to calibrate the room temperature
Maximum temperature limit
2
Defines the adjustable temperature upper limit
Minimum temperature limit
3
Defines the adjustable temperature lower limit
Anti-frost
4
Activation temperature for frost protection
5
Response range: Accuracy
Heat protection
6
Software version
7
To calibrate the temperature, take another thermometer as the temperature ref-
erence and compare the measured temperatures. Press the "M & +" keys simul-
taneously in switched off state. Start with parameter 1. You can now calibrate the
temperature of the thermostat using the "+" and "-" keys.
22
Element
Range
-9°C to 9°C
5°C to 35°C
5°C to 35°C
5°C to 10°C
0.5 - 2°C
0: Off/1: ON