8
DMX
ADDRESS
Pri:
V input: 24 V DC
P input: 350 W max
Sec:
V output: 4x24 V-PWM
P output: 4x80 W
9
TEST SWITCHING
AT 20%
10
120 oHm
RESISTOR
11
LED SIGNAL
POWER ON
LED SIGNAL
12
DMX
13
LED SIGNAL
FAILURE
UK
DE
CZ
on
20%
In system with several DMX controllers connected to each other, connect only 1 control-
ler as "master device". More controllers set as "master" will create function problem in the
whole system.
Switching ON the first micro-switch and OFF the second when the system is turned on without
DMX signal all the fittings light up each channels at 20% off the maximum power. In this way it is
easy to spot any fault in the wiring.
Switching ON the first micro-switch and OFF the second the resistance at the end of DMX line
starts working. This operation must be done always on the last fitting of the DMX line.
LED Green off - NOT OK
LED Blue ON, DMX data receiving
LED Blue OFF, no DMX data
LED Red OFF, PWM OK
LED Red ON, PWM not OK
DK
EE
FI
FR
HU
IT
SHIELD
ADDRESSING SWITCHES:
- addresses from 1 to 512 channels;
- 3 channels;
- addresses 600, 601, 602: pre-set scenarii;
- addresses 700, 701, 702: the 1st luminaire like "master":
address 700,701 or 702. Other
resistor
luminaires like "slave": address 1.
after 5 sec LED Red ON, PWM not OK
after 5 sec LED Red ON, PWM not OK and the system goes in safety position.
You need to remove main current, to solve the problem on PWM, and put the
ACC
LED
1
3
9
LT
LV
NO
PL
SE
RU
20%
resistor
26258645 P- 0612