Descargar Imprimir esta página

Presto DL 400 SE Instrucciones De Instalación página 9

Ocultar thumbs Ver también para DL 400 SE:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 13
ENGLISH
1) INSTALLATION INSTRUCTIONS
2) PRECAUTIONS FOR USE (The product guarantee depends on compliance with these instructions)
INSTALLATION and USE
For products delivered with filters, these must be installed in accordance with the instructions.
Before commissioning any of our valves, it is essential to carefully drain
the pipes that can damage the mechanisms or water passages (PRESTO® heads that can be dismantled
from front).
Recommended operating pressure according to NF EN 816: 1 to 5 bars.
CLEANING
The chrome-plated coating of PRESTO® valves must be cleaned only with soapy water.
Abrasive, acid, alkaline or ammonia-based household products are prohibited.
MAINTENANCE
Never lubricate the internal mechanism, particularly the caps and valve seals.
3) Inlet
4) Top inlet
5) Top inlet without stop valve
6) Rear inlet
7) Top inlet - Legionella version
8) Rear inlet - Legionella version
9) REFERENCE
10) Delivered with
11) Straight stop valve + filter gasket
12) Angled stop valve + filter gasket
13) Plug
14) Screw VBA TC 4x40 + washers
15) FLOW RATE (l/min)
16) Regulator
17) INSTALLATION
18) Hydraulic Connection
19) Top inlet
19bis) Filter gasket
20) Rear inlet
21) Maintenance
Product delivered with integrated 8 L/min flow regulator, supplied with spare part 6 L/min regulator
Spare parts: (see catalogue)
-DL cartridge 20/35 sec
-Set of 20 self-cleaning needles
-Complete trigger
-Complete front plate/ rocker switch
-6 L, 8 L, 10 L/min regulator
1. Turn off the water inlet or close the stop valve
22) Dismantling the cartridge
23) Reassembly in reverse order
24) Replacing the shower head grid Ref. 90185 (grid only)
−Unscrewing central screw
− Replacement
25) Trigger replacement
26) LEGIONELLA version connection
Ref.
PRESTO SHOWER TAP
DL400 SE WITH STRAIGHT STOP
27424
VALVE
PRESTO SHOWER TAP
27426
DL400 SE WITH ANGLED STOP
VALVE
27) This document is not contractual; we reserve the right to modify the characteristics of our products without
prior notice.
28) In order to avoid errors, verify properly the scale on paper with the indicated dimensions
29) PATENTED and REGISTERED MODELS
DESCRIPTION

Publicidad

loading