Operating Instruction
Safety notes
Even if a concentration under the LEL is
measured in a certain position of the device
in the room, e.g. at normal working height,
it is possible that there may be a higher con-
centration in the explosive range in other
parts of the room or the building.
Gas testing method
The gas testing method with forming gas 5/95
(5% hydrogen in nitrogen) was developed to
locate the smallest leaks, those that cannot
be located using acoustic methods. The selec-
tion of hydrogen gas means there is no inter-
ference from other gases such as methane or
sludge gas. Please contact Herth+Buss for a
detailed description of the method, including
practical examples if required.
www.herthundbuss.com
2

Operation

2.1 Operating controls

Intake pipe
LED for different
measuring ranges
Display
Function buttons
Charging socket
Charge control
Exhaust gas outlet

2.2 Putting the device into operation

Before putting the device into operation,
make sure the built-in rechargeable batte-
ry is fully charged. Details can be found in
Chapter 5.
Press and hold the On/
Off button for approx. 2
seconds. The device swit-
ches on. All the availab-
le segments are shown
briefly on the display.
Then the gas type display (H2) and the word
HEAt appear on the display, announcing the
start of the 50-second heat-up cycle.