Información de Seguridad .................................................................................................................................... Pg. 14
Descripción del Producto ..................................................................................................................................... Pg. 15
Espacio Libre a Combustibles ............................................................................................................................. Pg. 16
Sistema de Chimenea Mason-Lite ....................................................................................................................... Pg. 16
Apoyo a los Sistemas de Suelo ........................................................................................................................... Pg. 17, 18
Instalación con Piso Combustible ........................................................................................................................ Pg. 19
Lo Que Necesitarás ............................................................................................................................................. Pg. 20
Montaje de las Chimeneas .................................................................................................................................. Pg. 21 ~ 26
Escudo de Radiación Para-fuegos ...................................................................................................................... Pg. 28
Agregando una Línea de Gas .............................................................................................................................. Pg. 31
Agregando Conexiones Eléctricas ....................................................................................................................... Pg. 31
Apendice I ............................................................................................................................................................ Pg. 33
Apendice II ........................................................................................................................................................... Pg. 33
Garantía Limitada de por Vida ............................................................................................................................. Pg. 35
Debajo vera una muestra de la placa que se encuentra en el interior de la parte inferior de la cúpula de su chimenea . Número
de modelo , fecha de fabricación y número de serie debe estar estampado en la placa donde se indica:
.12"
MFI
6391 Jurupa Ave.
Riverside, CA 92514
LARR No. 25924
MODEL
No.:
WARNING
!
HAS BEEN TESTED FOR USE ONLY
WITH APPROVED GLASS DOORS.
TO REDUCE THE RISK OF FIRE OR
4.25"
4.00"
INJURY, CONSULT OWNER'S MANUAL.
THIS FIREPLACE IS
DESIGNED FOR USE ONLY
WITH SOLID WOOD LOGS,
PLUMBED LPG OR NG LOG
LIGHTERS OR PLUMBED ANSI
Z21.60 DECORATIVE GAS LOGS.
Consult instructions included with
this firebox for further information.
LISTED MASONRY FIREPLACE SYSTEM COMPLIES WITH APPLICABLE REQUIREMENTS OF UL127 AND ULC610.
Fireplace is designed for installation per the National Fire Protection Association Standard
for Chimneys, Fireplaces, Vents and Solid Fuel-Burning Appliances (NFPA 211).
WARNING:
!
TO REDUCE THE RISK OF FIRE OR INJURY, DO NOT INSTALL AN UNVENTED GAS LOG SET INTO FIREPLACE.
DO NOT REMOVE THIS LABEL
Masonry
See MFI's installation and operating instructions for
Fireplace
Industries, LLC
this model. Contact local building officials about
restrictions and installation specifications in your area.
DATE
OF MFG.
MFP33
MFP39
WARNING:
Use only approved,
!
: THIS FIREPLACE
listed Chimney Pipe as follows:
MFP33/39/44: UL103-12"-Class A
(DM12-12", FMI 12" chimneys).
MFP49: UL103-14"-Class A
MFP63: UL103-16"-Class A
Please refer to pipe manufacturer's
installation instructions.
Chimney Height:
Max.: 40 ft.
Min.: 14 ft.
(17 ft. with 1 or 2 offset
sections maximum)
THIS APPLIANCE NEEDS FRESH AIR FOR SAFE OPERATION AND MUST BE INSTALLED
SO THERE ARE PROVISIONS FOR ADEQUATE COMBUSTION AND VENTILATION AIR.
THIS FIREPLACE HAS NOT BEEN TESTED WITH AN UNVENTED GAS LOG SET.
CONTENIDO
6.5"
6.25"
SERIAL
No.
MFP44
MFP49
FIREPLACE CLEARANCES TO COMBUSTIBLES:
UNIT FRONT, SIDES, REAR..............................................2" (51 mm)
COMBUSTIBLE FLOOR (MFP33/39/44/49)................6" (203 mm)
COMBUSTIBLE FLOOR (MFP63)...............................8" (203 mm)
COMBUSTIBLE SHEATHING ABOVE OPENING TOP...18" (457 mm)
SHEATHING OR TRIM TO OPENING SIDES...................8" (203 mm)
MANTLE ABOVE OPENING...........................................12" (305 mm)
OPENING TO SIDE WALL..............................................24" (610 mm)
HEARTH EXTENSION BEYOND FRONT.......................20" (508 mm)
HEARTH EXTENSION BEYOND SIDES........................12" (305 mm)
INSULATION FROM FIREBOX.........................................2" (51 mm)
MANTEL CLEARANCES
0" - 3" : 1-1/2" MAX. PROJ.
3" - 12" : 1-1/2" - 8" MAX. PROJ.
1
PFS
Tested &
File No.
Listed By
®
F08-154
C
US
ICC Evaluation
Services Report
No. 2401
MFP63
MANTEL ABOVE OPENING:
MIN. - 3" SHEATHING OR
TRIM TO OPENING SIDES 8"