8016
Description of Keypad and Terminal Board:
+
positive power supply (11V DC provided by power supply 6582)
-
negative power supply
C1
power relay contact input (output 1)
A1
power relay contact output (output 1)
OC
open collector output to pilot possible external relay (output 2)
green Led (lit to confirm code)
red Led (lit to indicate code error)
0-9: Keys for entry of codes
R:
Key to cancel operation
C:
Key to confirm code
Programming
Output activation CODE programming procedure:
1. Press R and key 5 at the same time until the green and red leds illuminate
alternately
2. Enter the Password (123 by default) within 10 seconds.
3. Press "C", with intermittent and simultaneous activation of the green and red
leds.
4. Enter the number of the output to be activated (1 = output 1; 2 = output 2; 3
= output 1 and 2)
5. Press "C"
6. Enter the code to be programmed
7. Press "C"
To program other codes, repeat the operation from point 1.
The maximum time for the phases from 4 to 7 is 60 seconds.
PASSWORD ( max 8 digits) programming procedure:
1. Press R and key 1 at the same time until the green and red leds illuminate
alternately
2. Enter the previous password within 10 seconds.
3. Press "C", with intermittent and simultaneous activation of the green and red
leds.
4. Enter the new password within 10 seconds.
5. Press "C"
OUTPUT 1 activation TIME programming procedure:
1. Press R and key 3 at the same time until the green and red leds illuminate
alternately
2. Enter the Password (123 by default) within 10 seconds.
3. Press "C", with intermittent and simultaneous activation of the green and red
leds.
4. Enter the activation time in seconds (max 9999 seconds)
5. Press "C"
The maximum time for the phases from 4 to 5 is 60 seconds.
OUTPUT 2 activation TIME programming procedure:
1. Press R and key 4 at the same time until the green and red leds illuminate
alternately
2. Enter the Password (123 by default) within 10 seconds.
3. Press "C", with intermittent and simultaneous activation of the green and red
leds.
4. Enter the activation time in seconds (max 9999 seconds)
5. Press "C"
The maximum time for the phases from 4 to 5 is 60 seconds.
Programming procedure for the "DEVICE OPERATION"
1
Press R and push-button 6 at the same time.
2
Dial the Password (default value: 123) within 10 seconds
3
Press "C"
4
Dial the number according to table 1
5
Press push-button "C"
Table 1. Operation programming (* default value).
Relay output 1
Relay output 2
Timed
Timed
Timed
On/Off
On / Off
Timed
On / Off
On / Off
The maximum time for phases 4 and 5 is of 60 seconds.
Procedure for DELETING 1 code:
To program other codes, repeat the operation from point 1. The maximum time for
the phases from 4 to 5 is 60 seconds.
Procedure for DELETING ALL codes:
The maximum time for phase 4 is 60 seconds.
Enter Programming mode WITHOUT PASSWORD:
Example: programming of activation of output 1 with number 11223344 for six
seconds
Press R and key 5 at the same time, enter the password and press C, press key 1
and then C, enter the number 11223344 and then press C. Press R and key 3 at
the same time, enter the password and press C, press key 6 and then C.
The instruction manual is downloadable from the site www.vimar.com
Installation rules
Installation should be carried out by qualified personnel in compliance with the current regulations
regarding the installation of electrical equipment in the country where the products are installed.
Conformity
EMC directive
Standards EN 61000-6-1 and EN 61000-6-3.
REACH (EU) Regulation no. 1907/2006 – Art.33. The product may contain traces of lead.
Number to be pro-
Products for disposal can be consigned free of charge (without any new purchase obligation) to retailers
grammed
with a sales area of at least 400m
1*
for the environmentally friendly disposal of the used device, or its subsequent recycling, helps avoid the
potential negative effects on the environment and people's health, and encourages the re-use and/or
2
recycling of the construction materials.
3
4
1. Press R and key 2 at the same time until the green and red leds illuminate
alternately
2. Enter the Password (123 by default) within 10 seconds.
3. Press "C", with intermittent and simultaneous activation of the green and red
leds.
4. Enter the code to be deleted
5. Press "C"
1. Press R and key 2 at the same time until the green and red leds illuminate
alternately
2. Enter the Password (123 by default) within 10 seconds.
3. Press "C", with intermittent and simultaneous activation of the green and red
leds.
4. Press and hold R + 2 for 10 seconds (the keypad flashes)
1. Wire in a jumper on the two PIN_P contacts at the back of the terminal board
(Fig. 2)
2. Pres R and key 7 (simultaneously until the red led starts flashing)
3. Press the key combination for programming as described in step 1 of the
above procedures
(e.g. R + 5 to program an output)
4. Press C without entering the password
5. Follow the above-described procedures from step 4 onwards.
6. Remove the jumper from the two PIN_P contacts at the end of programming.
Pin_P
Fig. 2
WEEE - Information for users
If the crossed-out bin symbol appears on the equipment or packaging, this means the product
must not be included with other general waste at the end of its working life. The user must take
the worn product to a sorted waste center, or return it to the retailer when purchasing a new one.
, if they measure less than 25cm. An efficient sorted waste collection