Dip Switch Programming - Pyronix XD10TTAM Manual Del Usuario

Ocultar thumbs Ver también para XD10TTAM:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 49
XD10TTAM

5. Dip Switch Programming

1. 50/60Hz AC Filter
ON = 50Hz.
2. Anti-Mask Operation
ON = Anti-mask enabled
OFF = Anti-mask enabled only
system disarmed (see DIP4)
3. Blocking (via MW)
ON = Blocking disabled
OFF =Blocking enabled when
system disarmed (see DIP4 /
DIP6 has to be ON)
5. Sensitivity
ON = Auto Sensitivity
6. Open Mask and Alarm Relays
ON = Mask & alarm relays open
7. Buzzer Alarm
ON = Buzzer Enabled
8. LED Enable/Disable
ON = LED Enabled (Remote LED disabled)
OFF = LED Disabled (Remote LED enabled)
To remotely enable the LEDs:
Connect LED to walk test PGM: 0V = Walk Test On. 12V = Walk Test Off
OFF = 60Hz (For use with AC supplies at 60Hz)
4. RI 1 mode
ON = RI disabled
OFF = RI enabled
RI is used to enable the Anti-masking and
Blocking feature when DIP2 and DIP3 are
programmed to OFF. It is required to connect
the RI input to an output that follows the Arm/
Disarm status of the panel and gives Negative
(0v/-/GND) when disarmed and Positive
(COM/+/12v) when armed.
OFF = High Sensitivity
OFF = Mask relay open
OFF = Buzzer Disabled
Page: 6

Publicidad

Tabla de contenido
loading

Tabla de contenido