Allmatic AV Manual De Instrucciones página 9

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

5.2 Pedestrian function.
ENABLE
SETTING THE PEDESTRIAN
PRESS 4 TIMES SEL
Work. time
CODE
Work. time
Mode
CODE
SEL. OR MOD
5.3 Electric lock (only on AV1 with optional card).
ENABLE
PRESS 5 TIMES SEL
Auto.clo
Work.time
Auto.clo
mode
Work.time
TO DISABLE IT
Use the SELECTION key on the electric lock ability (WORK TIME & AUTO CLOSE LED FLASHING). Pressing the MODE key again will disable
the function with the relative signalling of the two LEDS: WORK TIME and AUTO CLOSE LIT for a few seconds.
In the event that the function is activated on the AV version, you will note a delay of 1 second in the opening phase.
5.4 Allmatic or customized variable code:
Enable
PRESS 6 TIMES SEL
Code
Auto.ric
Code
mode
Auto.ric
5.5 Exit from the programming.
Every time that you alter the parameters the control box exits from the menu of this parameter. The time availble to act on the settings is 10 se-
conds. Otherwise the control box automatically exits from the programming phase.
Skipping the programming phase the 7th time that you press SEL determines the exit from the programming mode.
5.6 Reset.
SEL.
MODE
6-1622081
REV.11
27/07/2012
The control box is supplied with the pedestrian feature deactivated.
In order to use this function, the use of the 2nd transmitter channel is indispensable (see para-
graph 4).
FEATURE
Activation and setting:
1) Press 4 times on the SELECTION key, CODE and WORK TIME are lit.
2) Press the Mode key, the CODE and WORK TIME led are now flashing.
3) Exit from the configuration menu.
4) Press step by step key, the automation starts to open and continue to open until selection or
mode key are pressed. Once release the key, the motor stops and that position is memorised as
pedestrian run. Now, the second channel learned (b) will manage the pedestrian function. If we
want to change the pedestrian run, it's enough to repeat the procedure described upside.
To disable the pedestrian function:
Use the SELECTION key to disable the pedestrian feature. (Led CODE and WORK TIME FLA-
SHING). Pressing the MODE key again will disable the function with the relative signalling of the
two LEDS: CODE and WORK TIME ON for a few seconds. If disabled, each time it is re-enabled,
it will be necessary to reset the time.
The control box is supplied with the function desactivated.
To use this function, it's necessary to use the optional additional card.
There is an auxiliary output for the use of an electric lock. The activation time is 3 SECONDS fixed. With a closed
gate, giving a command of opening the activation is immediate and the gate has a delay of 1 second. The electric
lock remains active for another two seconds after the start of the movement.
To enable this function:
1. Press 5 times the key SELECTION, the WORK TIME & AUTO CLOSE Led LIT
2. Pressing the MODE key once will ENABLE the ELECTRIC LOCK feature and the signal will be given by way of
a few FLASHES of WORK TIME and AUTO CLOSE.
Allmatic / Customized variable code:
The unit is fitted with the Allmatic variable decoding code.
Enable:
1) Press 6 times the key SELECTION, The Code and Auto.ric led are now lit.
2) Press the key MODE, The led code and Auto ric flash for a few second.
3) Reset the control unit pressing in the same time the key selection and mode.
TO ENABLE THE ALLMATIC VARIABLE CODE DECODING
Act on the SELECTION key to use the new parameter (Led CODE and AUT RECL. FLASHING). A pressure of the
MODE key shall again enable the Allmatic variable code coding, and the signalling will be given by the permanent
lighting of the CODE and AUT RECL leds . Reset the control unit.
To reset the control unit with the factory settings, or to vary between receipt with fixed code or variable code, press
the SELECTION AND MODE keys CONTEMPORARILY: all the LEDS will light up, flash and then turn off.
ITA
ENG
FRA
ESP
DEU
POR
3 /5

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Av1

Tabla de contenido