Descargar Imprimir esta página

Publicidad

Enlaces rápidos

UPS400N & UPS600N – UNINTERRUPTABLE POWER SUPPLY
1. Introduction
The UPS400N and the UPS600N have a wide input voltage range and are equipped with a cold-start function to allow startup in case of a
blackout.
1) main switch (including cold-start function)
2) LED
3) AC input fuse
4) outlets
5) RJ11 jacks
6) communication port
Note that the necessary cables and software are included.
2. Installation and Operation
Make sure the device was not damaged in transit. Notify your dealer immediately in case of damage. Keep the original packaging material
for possible future use.
1) Connect the power cord to a grounded receptacle.
2) Charge the batteries for ten hours prior to use. The UPS will recharge the batteries automatically whenever its power cord is plugged into
a wall outlet. You may use the UPS immediately without recharging, but the backup time will be less than the rated period.
3) Connect the power cord of your computer equipment to the output receptacles of the UPS.
4) Switch on the computer equipment. Press the front panel switch to activate the UPS. The LED will light and the UPS is now ON.
5) Unplug the power cord of the UPS to test the backup function. The power LED of the UPS wll light intermittenly and the alarm will sound
every 2 seconds.
3. Storage
For storage in moderate climates : plug the power cord into a wall receptacle for 12 hours every 3 months to recharge the batteries. Repeat
this procedure every 2 months in warmer climates.
4. Troubleshooting
In case of trouble you should check the wall receptacle and verify whether the AC voltage is inside the limit values.
Use the following table if necessary :
Problem
No light, no alarm
Less backup time
UPS400N & UPS600N – UNINTERRUPTABLE POWER SUPPLY
1. Inleiding
De UPS400N en de UPS600N hebben een groot ingangsspanningsbereik en zijn uitgerust met een koudstartfunctie om activering bij
stroomonderbreking mogelijk te maken.
1) hoofdschakelaar (met koudstartfunctie)
2) LED
3) AC ingangszekering
4) uitgangen
5) RJ11 jacks
6) communicatiepoort
Merk op dat de benodigde kabels en software worden meegeleverd.
UPS400N & UPS600N
Possible Cause
1. blown AC fuse
2. power cord is loose
3. main switch is not ON
1. battery is not full charged
2. battery is out of order
3. charger is defective
1
Solution
1. replace AC fuse with identical one
2. connect AC power cord to wall
receptacle properly
3. press the main switch
Please recharge the battery for at least 6
hours. Contact your dealer if the problem
persists.
VELLEMAN

Publicidad

loading

Resumen de contenidos para Velleman UPS400N

  • Página 1 UPS400N & UPS600N – UNINTERRUPTABLE POWER SUPPLY 1. Introduction The UPS400N and the UPS600N have a wide input voltage range and are equipped with a cold-start function to allow startup in case of a blackout. 1) main switch (including cold-start function)
  • Página 2 Raadpleeg uw dealer indien het probleem 3. lader is defect niet opgelost raakt. UPS400N & UPS600N – UPS DE SAUVEGARDE 1. Introduction Ces UPS ont une large plage de tension d'entrée et ils sont pourvus d'une fonction démarrage à froid pour permettre l'activation en cas d'une interruption de courant.
  • Página 3 Consultez votre revendeur si le 3. le chargeur est défectueux problème persiste. UPS400N & UPS600N – SISTEMA DE ALIMENTACIÓN ININTERRUMPIDA (SAI/UPS) 1. Introducción Estas alimentaciones ininterrumpidas tienen un gran alcance de tensión de entrada y están provistas de una función de arranque en frío para permitir la activación en caso de caída de la red eléctrica.
  • Página 4 3. el cargador está defectuoso UPS400N & UPS600N – UNTERBRECHUNGSFREIE STROMVERSORGUNG (USV/UPS) 1. Einführung Die UPS400N und die UPS600N haben einen großen Eingangsspannungsbereich und verfügen über eine Kaltstart-Funktion um eine Aktivierung bei Stromausfall zu ermöglichen. 1) Hauptschalter (mit Kaltstart-Funktion) 2) LED 3) AC-Eingangssicherung 4) Ausgänge...

Este manual también es adecuado para:

Ups600n