INTRODUCTION
Technical Features:
• Cover Options: Cast Iron - White Porcelain.
• Surface Mounted.
• Sensor Operated - Adjustable Detection Range: 2-6 inches (5-15 cm).
• Voltage: 110 - 120 Volt at 50/60 Hz and 220-240 Volt at 50/60 Hz with - CE option.
NOTE: For dryer to function properly, a minimum of 16 inches (41 cm) should be spaced between
the hand dryer sensor and any obstruction such as shelves, hand washing stations, or any type
of reflective surface.
MACHINE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED TECHNICIAN
INSTALLATION
1. Dismantling for installation
Note: Sensored model has a proximity sensor
mounted to the cover near the air outlet.
• Unscrew lock screws with security wrench
provided (P/N: P15-419).
• Remove cover vertically, taking care to avoid:
- Damaging internal components.
- Damaging cover (See Figure 1).
2. Mounting
Be sure power supply is disconnected prior to
mounting
Concealed wiring mounting must be done as follow:
• Put the wiring through before
tightening up the base on the wall.
• Use the template provided for wall fixing.
• Drill 4 holes with diameter of 5/16" (8 mm), taking care to clean the dust.
• Screw the base firmly to the wall using a 1/4" (6 -7 mm) flat-ended screwdriver.
Figure 3
See annexe for more information about mounting instructions
1
MOUNTING INSTRUCTIONS.
• To mount onto wall, be sure there are no hidden
electrical circuits or pipes in the mounting location.
• Place the mounting template (provided) on the wall
to mark location of four mounting screw holes.
• Drill four holes (Fig.1) Ø 5/16 inches (Ø 8mm)
diameter and inches 1 ¾ (45 mm.) depth.
• Take off the residual dust from the holes.
• Insert nylon plugs (provided) into four holes
(Fig.2-3).
• Place base plate on wall (Fig.4).
• Fix the base plate firmly on the wall (Fig.5-6).
Figure 1
Figure 2
ANNEX / ANNEXE
MOUNTING ITEMS PROVIDED.
• 4 screw.
• 4 Plug.
• 1 Mounting template.
• 1 Instruction manual.
www.bradleycorp.com
INSTRUCTIONS DE MONTAGE.
• En cas de montage sur un mur, s'assurer qu'aucun circuit
électrique et qu'aucun tuyau ne sont dissimulés derrière
l'emplacement choisi pour le montage.
• Placer le modèle de montage (fourni) sur la paroi pour
marquer l'emplacement des quatre trous pour les vis.
• Percer quatre trous (Figure 1) de 5/16" (8 mm) de diamètre,
et de 1 3/4" (45 mm) de profondeur.
• Enlever la poussière des trous.
• Insérer les chevilles en nylon (fournies) dans les quatre
trous (Figures 2-3).
• Placer la plaque de base sur la paroi (Figure 4).
• Fixer solidement la plaque de base sur la paroi
(Figures 5-6).
ÉLÉMENTS DE MONTAGE FOURNIS.
• 4 vis.
• 4 chevilles.
• 1 Modèle de montage.
• 1 Manuel d'instructions.