Leak Shield
Drain Port
7. Install the Waterway
Orient the leak shield with the drain port down and the arrow
pointing "UP."
Insert the leak shield into the rough opening.
IMPORTANT! If the waterway cannot be threaded onto the
adapter, remove the pipe nipple and install a longer one.
Using the provided waterway tool, thread the waterway to the
adapter.
NOTICE: Keep the waterway installation tool. This tool is needed
to remove the waterway for cleaning or servicing.
Verify the waterway is centered in the leak shield.
IMPORTANT! If the leak shield is loose after the waterway is
installed, remove the pipe nipple and install a shorter one.
Verify the leak shield is still positioned with the drain port down
and the arrow pointing "UP." The leak shield should be snug to
the wall and not move or shift.
1080947-2-D
Adapter
8
Waterway
Waterway Tool