128mm
CS-2
For Auxiliary Line
Para línea auxiliar
Flood Prevention Switch for Drain Lines with an Elbow Fitting
Interruptor para prevención de inundaciones para líneas de drenaje con ajuste de codo.
The DiversiTech CS-2 overflow prevention switch is designed to cut power to an air conditioning system if a clog in the
condensate drain line occurs. The CS-2 uses a state of the art magnetic reed float switch with an integrated LED
indicator notifying the homeowner and/or technician that the flood switch has activated, cutting power to the system
and reducing the risk of a flood and water damage. Additional benefits of the CS-2 include a "Pull To Test" lever for
verifying correct installation, and an internal surge protector eliminating the risk of inadvertent shutdowns that may
inconvenience a homeowner. This product is plenum rated.
El interruptor de prevención de desbordamientos DiversiTech CS-2, está diseñado para interrumpir la energía de un sistema de aire acondicionado
si ocurre una obstrucción en la línea de drenaje condensado. El CS-2 utiliza un interruptor flotante de lámina magnética de última tecnología, con
un indicador de LED integrado notificando al propietario y/o técnico que el interruptor de inundaciones se ha activado, interrumpiendo la energía del
sistema y reduciendo el riesgo de un desbordamiento y daño por agua. Los beneficios adicionales de CS-2 incluyen una palanca de "activar para
probar" para verificar la instalación correcta, y un protector de sobrecarga interno que elimina el riesgo de apagones involuntarios que pueden
causar inconvenientes al propietario. Este producto tiene clasificación de pleno.
Small Size for Serviceability
LED Light Indicator
Pequeño tamaño para mantenimiento
Indicador de luz LED
Jumper Wire
Cable de puente
Proven Switch Design
Diseño de interruptor comprobado
Plenum Rated
Pleno clasi cado
WARNING: Cancer and Reproductive Harm - For more information, go to
www.P65Warnings.ca.gov
ADVERTENCIA: Cáncer y daños reproductivos – para más información vaya a
www.P65warnings.ca.gov
DiversiTech Corporation
www.diversitech.com
95247 14885
0
1
800.995.2222
DOC32387
0819
Assembled in China
B18-519
256mm
Pull To Test
Activar para probar
Versatile & Durable
Versátil y duradero
To keep condensate drain lines and
pans clear and free from buildup,
use
Pro-Treat
®
tablets
or
Flow-Plus
pan treatment.
®
Add monthly or as needed.
Para mantener las líneas de drenaje y las
bandejas de condensado limpias y sin uso
acumulativo use tabletas de Pro-Treat
o
®
tratamiento de bandeja Flow-Plus
.
®
Agregar mensualmente o según sea necesario.
128mm
CS-2
PLENUM RATED
PLENO CLASIFICADO
Condensate Drain Line Switch
Auxiliary Line
Línea auxiliar
SERVICEABLE -
Unique "Pull To Test" Lever
PRÁCTICO -
Palanca única de "activar para probar"
SIMPLE -
LED Indicator Light for Fast Troubleshooting
SENCILLO -
Indicador con luz LED para resolución rápida de problemas
PROVEN - Most Reliable Magnetic Reed Switch with Voltage Surge Protection
PROBADO -
El interruptor de lámina magnética más confiable con protección contra descargas de voltaje
VERSATILE -
Easy Installation in Plenum Rated and Standard Applications
VERSÁTIL -
Fácil instalación en aplicaciones de pleno clasificadas y estándar
PIPE
TUBERÍA
ETL CLASSIFIED
5010060
5010060
Conforms To
Conforms To
UL STD 508
UL STD 2043
Certified To
Certified To
CSA STD C22.2 # 14
ULC STD S142
194mm

Publicidad

loading

Resumen de contenidos para DIVERSITECH CS-2

  • Página 1 CSA STD C22.2 # 14 ULC STD S142 si ocurre una obstrucción en la línea de drenaje condensado. El CS-2 utiliza un interruptor flotante de lámina magnética de última tecnología, con PROVEN - Most Reliable Magnetic Reed Switch with Voltage Surge Protection un indicador de LED integrado notificando al propietario y/o técnico que el interruptor de inundaciones se ha activado, interrumpiendo la energía del...
  • Página 2 DISCONNECT POWER TO HVAC SYSTEM AT CIRCUIT BREAKER BEFORE INSTALLING CS-2. INFORMACIÓN IMPORTANTE RELATIVA AL CABLE DE PUENTE DESCONECTAR LA ENERGÍA DEL SISTEMA HVAC EN EL INTERRUPTOR DE CIRCUITOS ANTES DE INSTALAR CS-2. DO NOT GLUE THE SENSOR ASSEMBLY TO THE PIPE HOUSING. THE SENSOR ASSEMBLY IS REMOVABLE FOR INSPECTION THE CS-2 USES A VERY SMALL CURRENT TO LIGHT THE LED.