Description
Jet pumps are single stage domestic water
pumps designed for pumping potable
water in applications where the water is up
to 100 feet (deep well pump). A pressure
switch is a standard feature. A built-in
control valve is available on deep well
pumps. Deep well pumps can be mounted
to either a pre-charged, conventional type
or free standing pressure tank.
Unpacking
After unpacking the jet pump, carefully
inspect for any damage that may have
occurred during transit. Check for loose,
missing or damaged parts.
Safety Guidelines
This manual contains information
that is very important to know
and understand. This information
is provided for SAFETY and to
PREVENT EQUIPMENT PROBLEMS. To
help recognize this information, observe
the following symbols.
Danger indicates an
imminently
hazardous situation which, if not avoided,
WILL result in death or serious injury.
Warning indicates a
potentially
hazardous situation which, if not avoided,
COULD result in death or serious injury.
Caution indicates a
potentially
hazardous situation which, if not avoided,
MAY result in minor or moderate injury.
Notice indicates
important
information, that if not followed, may
cause damage to equipment.
NOTE: Information that requires special
attention.
Blue Angel Pumps
© 2009
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or
maintain the product described. Protect yourself and others by observing all safety information. Failure to
comply with instructions could result in personal injury and/or property damage! Retain instructions for
future reference.
Convertible Well Jet Pump
Water Systems
General Safety
Information
CALIFORNIA PROPOSITION 65
including lead, known to the State of
California to cause birth defects and
other reproductive harm. Wash hands
after handling.
GENERAL SAFETY
1. Read all manuals included with this
product carefully. Be thoroughly
familiar with the controls and the
proper use of the equipment.
2. Know the pump application,
limitations and potential hazards.
to match the system pressure rating and
the maximum flow rate.
or explosive fluids such as gasoline,
fuel oil, kerosene, etc. Do not use in
explosive atmospheres. Pump should
only be used with liquids compatible
with pump component materials.
Failure to follow this warning can result
in personal injury and/or property
damage.
pressure from the system before
attempting to install, service, relocate
or perform any maintenance. Lock the
power disconnect in the open position.
Tag the power disconnect to prevent
unexpected application of power.
to prevent entrapment of swimmers.
3. Drain all liquids from the system
before servicing.
REMINDER: Keep your dated proof of purchase for warranty purposes!
Attach it to this manual or file it for safekeeping.
For parts, product & service information
visit www.blueangelpumps.com
CBS50, CBS75 and CBS100
4. Secure the discharge line before
This product
5. Check hoses for weak or worn
contains chemicals,
6. Periodically inspect pump and
7. Personal Safety:
Always install a
pressure relief valve
Do not use to
pump flammable
8. Do not pump chemicals or corrosive
9. When installing pump, cover the
Disconnect power
and release all
10. Always test the water from the well
Install a screen
11. Complete pump and piping system
around the inlet pipe
starting the pump. An unsecured
discharge line will whip and possibly
cause personal injury and/or
property damage.
condition before each use. Make
certain all connections are secure.
system components. Perform routine
maintenance as required (See
Maintenance).
a. Wear safety glasses at all times
when working with pumps.
b. Keep work area clean, uncluttered
and properly lighted replace all
unused tools and equipment.
c. Keep visitors at a safe distance
from work area.
d. Make the workshop child proof:
use padlocks, master switches and
remove starter keys.
liquids. Pumping these liquids
shortens the life of the pumps seals
and moving parts and will void the
warranty.
well to prevent foreign matter from
falling into well and contaminating
the water and damaging internal
mechanical pumping components.
for purity before use. Check with
local health department for test
procedure.
MUST be protected against below
freezing temperature. Freezing
temperatures could cause severe
damage and void the warranty.
340002-002 3/09

Publicidad

loading

Resumen de contenidos para Blue Angel Pumps CBS50

  • Página 1 CBS50, CBS75 and CBS100 Operating Instructions and Parts Manual Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.
  • Página 2: Pre-Installation

    CBS50, CBS75 and CBS100 Operating Instructions & Parts Manual General Safety TANKS - CONVENTIONAL STORAGE Information The function of the tank is to store a (Continued) quantity of water under pressure. When Grounded Pin full, the tank contains approximately 12.Do not run the pump dry or damage...
  • Página 3 CBS50, CBS75 and CBS100 Operating Instructions & Parts Manual Pre-Installation Slope all inlet piping upwards towards the pump to prevent trapping air. To Pump (Continued) Unions or hose couplings can be installed near pump to facilitate removal PACKAGE SYSTEMS Well for servicing or storage.
  • Página 4 CBS50, CBS75 and CBS100 Operating Instructions & Parts Manual Installation (Continued) CHART 2 - PIPE SIZING DRIVEN WELL Horizontal Distance (Feet) • Drive the point several feet below Pump the water table. Pump Model Opening 0-25 26-100 NOTE: A packer type foot valve can...
  • Página 5 CBS50, CBS75 and CBS100 Operating Instructions & Parts Manual Installation Electrical (Continued) Prime Outlet Pressure Plug 7. Slope both pipes upward toward Risk of electrical Switch Suction the pump to eliminate trapping shock. This pump is designed for indoor installation only.
  • Página 6 CBS50, CBS75 and CBS100 Operating Instructions & Parts Manual Electrical 6. Let the system operate for several DRAINING THE TANK (Continued) minutes to flush all pipes. Conventional tanks can be drained by Check selector to voltage supply. They 7. Close faucet and allow pump to opening an outlet at the lowest point must match change if needed.
  • Página 7 CBS50, CBS75 and CBS100 Operating Instructions & Parts Manual Maintenance 7. With a large screwdriver or 2. Carefully slip seal plate over shaft (Continued) adjustable wrench, keep the shaft so as not to disturb seal position in from rotating and remove the seal plate.
  • Página 8 CBS50, CBS75 and CBS100 Operating Instructions & Parts Manual www.blueangelpumps.com...
  • Página 9: Troubleshooting Chart

    CBS50, CBS75 and CBS100 Operating Instructions & Parts Manual Troubleshooting Chart Symptom Possible Cause(s) Corrective Action Pump will not run 1. Power off 1. Turn power on or call power com pa ny 2. Blown fuse or tripped breaker 2. Replace fuse or reset circuit break er 3.
  • Página 10: Replacement Parts List

    CBS50, CBS75 and CBS100 Operating Instructions & Parts Manual For Replacement Parts or Technical Assistance, Call 1-888-636-6628 Please provide following information: Address any correspondence to: - Model number Blue Angel Pumps - Serial number (if any) 101 Production Drive - Part description and number as shown in parts list Harrison, OH 45030 U.S.A.
  • Página 11 CBS50, CBS75 and CBS100 Operating Instructions & Parts Manual Performance Discharge Pressure psi Suction Model No. Motor HP Lift (Feet) Output in Gallons Per Hour (GPH) CBS50 1140 1140 1014 1014 CBS75 1260 1218 1140 1140 CBS100 Vertical Distance to Pumping Level...
  • Página 12 Limited Warranty For three years from the date of purchase, Blue Angel Pumps will repair or re place, at its option, for the original purchaser any part or parts of its Pond Kit, Sump Pumps or Water Pumps (“Product”) found upon examination by Blue Angel to be defective in materials or work man ship.
  • Página 13 CBS50, CBS75 et CBS100 Instructions D’utilisation et Manual de Pièces Veuillez lire et conserver ces instructions. Lire attentivement avant de commencer à assembler, installer, faire fonctionner ou entretenir l'appareil décrit. Protégez-vous et les autres en observant toutes les informations sur la sécurité. Négliger d'appliquer ces instructions peut résulter en des blessures corporelles et/ou en des dommages matériels ! Conserver ces instructions pour références ultérieures.
  • Página 14 CBS50, CBS75 et CBS100 Instructions D’utilisation et Manual de Pièces Généralités Sur La EAU SOUTERRAINE telle qu’indiquée sur la Figure 1. Le fil conducteur vert (ou vert et jaune) Sécurité L’eau existe dans la strate souterraine à (Suite) dans le cordon est le fil de terre. Le plusieurs niveaux.
  • Página 15 CBS50, CBS75 et CBS100 Instructions D’utilisation et Manual de Pièces TABLEAU 1 - MONTAGES DE POMPE À JET/RÉSERVOIR l’aspiration de sable ou de sédiment Contrôle de dans le système. Volume d'Air 4. Une fois que la profondeur correcte Type Requis...
  • Página 16 CBS50, CBS75 et CBS100 Instructions D’utilisation et Manual de Pièces Installation (Suite) TABLEAU 2 - TAILLES DE TUYAUX Distance Horizontale du puits par l’eau de surface ou (Metres) autres polluants. Modèle de Ouverture de Pompe Pompe 0-7,62 7,93-30,5 5. Incliner le tuyau horizontal en haut vers la pompe pour empêcher...
  • Página 17 CBS50, CBS75 et CBS100 Instructions D’utilisation et Manual de Pièces Installation pour puits profond en pompe pour puits de (Suite) Bouchon Sortie surface. Le jet pour puits de surface a une d'Amorçage À déplacer le jet du haut en bas afin Manostat arrivée de 1 po NPT et une ouverture pour...
  • Página 18 CBS50, CBS75 et CBS100 Instructions D’utilisation et Manual de Pièces Électrique 1. Enlever le bouchon d’amorçage. Le système est maintenant en marche et (Suite) fonctionnera automatiquement au besoin. 2. Remplir la pompe et la tuyauterie est peinturée verte et est identifiée par complètement d’eau.
  • Página 19 CBS50, CBS75 et CBS100 Instructions D’utilisation et Manual de Pièces Entretien (Suite) 4. Séparer le carter de la pompe Trous (volute) du moteur afin d’exposer le de Vis REMARQUE: Lors du remplissage du diffuseur et la plaque d’étanchéité. réservoir par la pompe, le contrôle de 5.
  • Página 20 CBS50, CBS75 et CBS100 Instructions D’utilisation et Manual de Pièces 20 Fr...
  • Página 21 CBS50, CBS75 et CBS100 Instructions D’utilisation et Manual de Pièces Tableau de dépannage Symptôme Cause(s) Possible(s) Mesures Correctives La pompe ne 1. Hors Circuit 1. Mettre la pompe en marche ou contacter la compagnie fonctionne pas d’électricité 2. Fusible sauté ou disjoncteur enclenché...
  • Página 22: Liste De Pièces De Rechange

    CBS50, CBS75 et CBS100 Instructions D’utilisation et Manual de Pièces Pour Pièces de Rechange ou Assistance Technique, Appeler 1-888-636-6628 S’il vous plaît fournir l’information suivante: Adresser toute correspondance à : - Numéro de Modèle Blue Angel Pumps - Numéro de série (si présent) 101 Production Drive - Description et numéro de la pièce...
  • Página 23 CBS50, CBS75 et CBS100 Instructions D’utilisation et Manual de Pièces Performance Hauteur Pression de Décharge kPa d'Aspiration N° de Modèle HP de Moteur (Metres) Debit en Litres Par Heure (L/h) 1,52 3444 3217 2233 1385 3,05 2952 2725 1968 1226...
  • Página 24: Garantie Limitée

    Garantie Limitée Pendant trois ans à compter de la date d’achat, Blue Angel Pumps va réparer ou remplacer, à sa discrétion, pour l’acheteur original toute pièce ou pièces du Kit D’Étang, de ces Pompes De Puisard ou Pompes À Eau ("Produit") déterminées défectueuses, par Blue Angel, soit pour les matériaux ou la fabrication.
  • Página 25 CBS50, CBS75, y CBS100 Manual de instrucciones de operación y piezas Por favor lea y guarde estas instrucciones. Léalas cuidadosamente antes de tratar de montar, instalar, operar o dar mantenimiento al producto aquí descrito. Protéjase usted mismo y a los demás observando toda la información de seguridad.
  • Página 26: Preinstalación

    CBS50, CBS75, y CBS100 Manual de instrucciones de operación y piezas tierra, como se muestra en la Figura 1. Informaciones Generales AGUAS SUBTERRÁNEAS El conductor verde (o verde y amarillo) El agua que se encuentra en los diversos de Seguridad (Continued) del cordón es el alambre a tierra.
  • Página 27: Instalación

    CBS50, CBS75, y CBS100 Manual de instrucciones de operación y piezas localizada a 7,5 m (25 pies) en sentido Pre-Instalación Los tubos deben estar limpios y no (Continued) vertical del nivel de agua. Las instalaciones estar oxidados ni con descamaciones.
  • Página 28 CBS50, CBS75, y CBS100 Manual de instrucciones de operación y piezas Instalación (Continued) que la tubería de entrada tenga la m (25 pies), use tubos de los tamaños suficiente profundidad para que esté que se recomiendan en la Tabla 2.
  • Página 29: Eléctricas

    CBS50, CBS75, y CBS100 Manual de instrucciones de operación y piezas Instalación 1. Instale el control del volumen de DONVERSIÓN DE LA BOMBA PARA (Continued) aire en el tanque como se muestra. POZOS PROFUNDOS PARA QUE OPERE EN 2. Lubrique los empaques de caucho UN POZO POCO PROFUNDO (FIGURA 9) 2.
  • Página 30: Funcionamiento

    CBS50, CBS75, y CBS100 Manual de instrucciones de operación y piezas Instalación Desconecteel El sistema está ahora en funcionamiento y (Continued) suministro eléctrico hará ciclos automáticos según la demanda. y libere toda la presión del sistema antes La unidad sólo tiene un terminal adecuado...
  • Página 31 CBS50, CBS75, y CBS100 Manual de instrucciones de operación y piezas Eléctricas 2. Reemplace el tanque. 9. Planquee la pieza rotatoria de (Continued) sellado del eje para que salga del NOTA: Si la cámara elástica tiene fugas 2. Drene todas las tuberías hasta un impulsor (Figura 14).
  • Página 32 CBS50, CBS75, y CBS100 Manual de instrucciones de operación y piezas Mantenimiento sobre el difusor. En todas las aplicaciones 3. Sitúe la pieza rotatoria del sello del en pozos poco profundos se debe eje en el impulsor y presiónela para...
  • Página 33: Tabla De Identificación De Problemas

    CBS50, CBS75, y CBS100 Manual de instrucciones de operación y piezas Tabla de Identificación de Problemas Síntoma Causa(s) Posible(s) Medida Correctiva La bomba no 1. No hay energía eléctrica 1. Encienda la corriente eléctrica o llame a la compañía de funciona suministro eléctrico...
  • Página 34: Lista De Partes De Reparación

    CBS50, CBS75, y CBS100 Manual de instrucciones de operación y piezas Para Ordenar Repuestos o Asistencia Técnica, Sírvase Llamar al Distribuidor Más Cercano a Su Domicilio Sirvase darnos la siguiente información: Dirija toda la correspondencia a: - Número del modelo Blue Angel Pumps - Código impreso...
  • Página 35: Rendimiento

    CBS50, CBS75, y CBS100 Manual de instrucciones de operación y piezas Rendimiento Succión de Presión de Descarga bar Elevación 1,38 2,07 2,76 3,45 No. de Modelo Motor CP (metros) Entrega en Litros por Hora (LPH) 1,52 3444 3217 2233 1385...
  • Página 36: Garantía Limitada

    Garantía Limitada Durante tres años a partir de la fecha de compra, Blue Angel Pumps reparará o reemplazará para el comprador original, según lo que decida, cualquier pieza o piezas de su Juego para estanque, Bombas de resumideros, Bombas de agua ("Producto") que después de un examen Blue Angel encuentre que tenían defectos en su material o mano de obra.

Este manual también es adecuado para: