Maintenance Recommendations - S&P DHUM-12 EN Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 1
Timer operation
By using the button
the end of the programmed period the device stops completely.
During the timer period, the display shows the time programmed, and the indicator
illuminated, indicating that the device is programmed to function for a limited time period.
Self-defrost cycle
The normal operating temperature range is +5ºC/+32ºC. Operation of the device outside this
range is not recommended.
The self-defrost function is initiated automatically by the device itself. It is activated for a pe-
riod of 5 minutes if the ambient temperature is below 15ºC approximately. When this function
is activated, the self-defrost indicator light
Self reset function
The device is equipped with a self reset function. In the event that the power supply is cut
temporarily for any reason, the unit resets itself automatically, retaining the parameters set
by the user before the power cut.
REMOVAL OF WATER
Removal of water by means of the tank
1. An intermittent sound signal accompanied by the illumination of the red light
that the water tank is full. The device will cease to operate until the user empties it (Fig. 3).
2. Once emptied, replace it inside the unit. When the indicator
the tank has been replaced correctly.
Precautions: Do not remove the tank too often. If this action is repeated over a series of short
periods, damage can be caused to the compressor. Wait until the tank is completely full.
Continuous water drainage
1. Remove the water tank, so that you can connect the pipe to the water outlet tube (Fig. 3).
2. Connect a PVC pipe with an interior diameter of 14 mm to the water outlet tube and secure
it with a nylon hose clip. The extraction tube must always be fl at to the fl oor and free of any
kink that might obstruct the fl ow of water.
3. Replace the water tank in the unit, and the latter will restart operating after 3 minutes
approx.

MAINTENANCE RECOMMENDATIONS

1. Disconnect the device from the power supply before carrying out any maintenance operation.
24
, the user can program a period of operation between 1h and 24h. At
illuminates.
goes out, this indicates that
is
, indicate

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Dhum-16 enDhum-20 enDhum-30 en

Tabla de contenido