GENERAL INFORMATION
The product is a new saving-energy sensor; it adopts good sensitivity detector and integrated circuit. It
gathers automatism, convenience, safety, saving-energy and practical functions. It utilizes the infrared energy
from human as control-signal source and it can start the load at once when one enters detection field. It can
identify day and night automatically. It is easy to install and used widely.
SPECIFICATION
Detection Range: 360°
Power Source: 110-240V/AC
Power Frequency: 50/60Hz
Time Delay: Min. 10sec±3sec
Max. 5min±1min
INSTALLATION
- Fix the holder in the place where you will
want to install according to figure on the right.
-After installation of the sensor, connect with
lamp and then you could test it.
TEST
- After installation, Turned LUX knob clockwise to the maximum (SUN). Turned time knob anti-clockwise to
the minimum (-).
-Switch on the power .The sensor and its connected lamp will have no signal at the beginning. After
Warm-up 30sec, the sensor can start work .If the sensor receives the induction signal, the lamp will turn on.
While there is no another induction signal any more, the load should stop working within 10sec±3sec and the
lamp would turn off..
- Turn LUX knob anti-clockwise on the minimum (moon). If the ambient light is more than 3LUX, the sensor
would not work and the lamp stop working too. If the ambient light is less than 3LUX (darkness), the sensor
would work. Under no induction signal condition, the sensor should stop working within 10sec±3sec.
Note: when testing in daylight, please turn LUX knob to
work!
INSTRUCCIONES IMPORTANTES DE SEGURIDAD
INSTRUCTIONS
MODEL 99896
Ambient Light: <3-2000LUX (adjustable)
Rated Load: Max.60W (E27)
Detection Distance: 6m max (<24ºC)
Installation Height: 2-3.5m
(SUN) position, otherwise the sensor lamp could not
-6-
+