TROUBLESHOOTING GUIDE
PROBLEM
Burner won't light
Burner won't stay
lit after lighting
Jul-01-2015
CAUSE
No Propane Gas at Burner
No Spark at Electrode
Lack of oxygen
Thermocouple not in flame
Thermocouple connection
at the main control valve is
loose
No Fire Ice on Burner
11
REMEDY
Check that gas tank valve is
open. Turn control knob to "ON"
and push control knob in. Make
sure tank has propane gas.
Check that AAA battery is
installed with negative (-) end first
and has a charge. Check that the
wire is connected to the ignition
module. Check that the electrode
is not cracked or broken.
Remove excess lava rocks or fire
ices from around the ignition well.
Check that the tip of the
thermocouple is even with the top
of the ignition well. Remove any
fire ice from the igntion well.
Tighten the thermocouple nut at
the back of
the valve.
Cover the burner with fire ice per
the instructions