D
- CONNECTING OF THE MASTER Wi-Fi OS
ATTENTION: Don't put MASTER Wi-Fi card inside of metal containers or a wall because it can cause a malfunction.. It is therefore recommended in these cases to add the
868MHz aerial code ACG5451 to apply to the metal casing for a perfect reception/transmission of the signals.
ATTENTION: ACTIVATE ON CONTROL PANELS THE PRE-FLASHING FUNCTION (IF AVAILABLE).
It is strongly advisable to setup an automatic closing time delay not longer than 1 minute.
Verify the presence of protection fuse in series on secondary of the control panel.
In case it is not available, please connect a T 200 mA delayed fuse in series on the MASTER power supply.
- Turn off power to the control panel.
NOTE: The opening of the gate occurs 2 seconds after a command. That is done to allow to MASTER Wi-Fi OS card to verify the correct functioning of the safety devices.
EDGE 2
green wire
COM
gray wire
EDGE 1
yellow wire
PHOT.N.C.
black wire
CONTROL BUTTON
white wire
A+ TEST
brown wire
MASTER Wi-Fi OS operates normally if it handles all the
remote controls (through its 433 MHz radio module) and
the wired controls (through its WHITE WIRE).
In case of external radio receivers and wired controls,
they must be connected to the WHITE WIRE.
* OBLIGATORY connection for panels with a 120/230V ac blinker output
** OBLIGATORY connection for panels with a 12/24V ac/dc blinker output. ATTENTION: CHECK POLARITY
!
The connection is compulsory also in those cases where the blinker is not installed in the system.
ATTENTION: Always connect the control panel blinker output to the MASTER Wi-Fi OS card terminals J4 if blinker output is 230V or connect to the wires of the J2
connector if blinker output is 12/24V. If the connection is not made, the door will not work and the buzzer emits 4 sounds indicating that the connection
is missing.
EDGE 2 INPUT (gray wire COM, green wire EDGE 2) dedicated to the safety strip device.
Input enabled only with JP2 on SX.
Attention: any wire jumper present on the SAFTETY STRIPS terminals of RIB control panels
must be removed.
EDGE 1 INPUT (gray wire COM, yellow wire EDGE 1) dedicated to the strip safety device.
Attention: any wire jumper present on the COM-EDGE terminals of control panels must
be removed.
PHOTOCELL INPUT (gray wire COM, black wire PHOT) dedicated to the photocell safety
devices.
Attention: any wire jumper present on the COM-PHOT terminals of control panels must
be removed.
CONTROL BUTTON (gray wire COM, white wire N.O. BUTTON)
Disconnect every wired command from the control panel and connect it to the WHITE WIRE
of MASTER Wi-Fi OS.
4 3 2 1
-
+
COM
12/24V ac/dc
K.BUTTON
4
3
2+
1-
Total opening
Power feed
control contact
12/24V ac/dc
COM-K BUTT/START
CONNECTION OF THE AUTOTEST INPUT (brown wire A+ TEST) for compliance with
standard EN 13849-2:2015
- If control panel used is equipped with autotest place jumper JP1 paying
attention to the control panel AUTOTEST power supply (negative or
positive/alternate - see relative instructions).
- Connect the A+ TEST output of the control panel to the brown wire of
the MASTER Wi-Fi OS in order to be able to check the safety devices
before every closing.
- If the MASTER Wi-Fi OS card control test fails, the control panel will
block the automation and the LED EDGE PHOT will indicate a safety
device issue flashing red/green.
The buzzer emits an alternating sound for 1 minute to signal the
problem.
The alarm status of the buzzer comes on again for 1 minute when a
control is given.
If the panel is not equipped with an auto test, the control test is
ignored.
19
*
120/230V ac
!
+
**
-
12/24V ac/dc
12/24V ac/dc
-
JP1
JP1
G
B
+/~