11 TROUBLESHOOTING
The following checklist will help to identify the source of the problem with your fridge
freezer. If after carrying out this checklist you are still unsure of the cause of the fault,
please contact your nearest ARB Fridge Freezer Service Agent.
1. The fridge freezer has stopped opera ing. The power LED does
not glow.
1.1
The power lead connections could be loose or dirty at the fridge
freezer or power supply end.
Check that the fridge freezer power lead connections have not become loose
or disconnected.
Check that the electrical contacts have not become dirty and are preventing
full voltage flow to the fridge freezer.
1.2
The fuse in the 12/24V DC cable plug may have blown.
Check the 12/24V DC cable plug fuse and replace if necessary. Refer to
section 6.17.
1.3
The cabinet fuse may have blown.
Check the cabinet fuse and replace if necessary. Refer to section 6.16.
2. The fridge freezer compressor has stopped operating. The power
LED is ORANGE.
2.1
The fridge freezer has reached the desired target cabinet
temperature.
The fridge freezer is operating correctly. No action is required.
3. The fridge freezer has stopped opera ing. The power LED is OFF
and the RED error LED is flashing.
3.1
The internal battery protection system has caused the fridge freezer
to switch off because the battery voltage is low.
The fridge freezer will automatically restart once the restart voltage is reached.
Refer to section 6.11 for switch off and restart voltages.
4. The fridge freezer does not cool or has stopped opera ing. The
power LED is green.
4.1
There may be an internal fault within the fridge freezer.
This can only be repaired by an authorised ARB Fridge Freezer Service Agent.
5. The control panel displays an error message (eg "ERR1") and he
fridge freezer does not cool.
5.1
The fridge freezer may have switched off due to an internal fault.
This can only be repaired by an authorised ARB Fridge Freezer Service Agent.
25
t
t
t
t