Unplug the power cord before cleaning your system. Also insert the black hat-like
plugs in the strainer opening to prevent water spillage. After completing all
maintenance tasks, you must plug the power cord back in and remove the plugs.
Titanium Electrode Cleaning
The titanium electrode has a self cleaning function incorporated into the electronic control's
programming. In most cases this self cleaning action will keep the electrode working at
optimum efficiency. If the pool water is hard (high mineral content) the electrode may require
periodic manual cleaning. To maintain maximum performance, we recommend that you open
and visually inspect the titanium electrode (7) monthly.
The following steps provide instructions on how to clean your cell.

Inspection and cleaning:

1. Switch off the unit, unplug the power cord from the electrical socket.
2. To prevent water from flowing out of the pool, unscrew the strainer grids from the strainer
connectors and insert the hat-like plugs into the strainer connectors.
3. Disconnect the 2 hoses from the Saltwater System (see drawings 1~3).
4. Unscrew the titanium electrode plug collar, disconnect the plug from the titanium electrode
(7) (see drawing 4).
5. Unscrew the cell nut, remove the titanium electrode from the cell housing (see drawing 5).
6. Place the titanium electrode in a container and pour kitchen grade vinegar into the
container until the titanium electrode is immersed. Soak for 1 hour and then flush with a
high-pressure garden hose (see drawing 6).
7. Reverse steps 3, 4, 5 and 6 to reconnect the electrolytic cell.
SAVE THESE INSTRUCTIONS