Troubleshooting:
Error
Device is not working
The device stop
working.
Oil runs out of the
device.
The lifting device is
difficult to operate or
is stuck.
Noise in the machine
head and overheated.
Only high speed, no
middle and low
speed.
Contact between
bowl and agitator.
Cause
No power supply.
Bowl not up
Protective grid open.
Gear not engaged.
Blown fuse.
Device overheated.
Gear wedged.
Protective grille inadmissibly
opened.
Bowl in the wrong position.
Transmission seal defective.
The lift guide is rusted or
contaminated.
Bad lubrication.
Transmission block for the gear
adjustment is defective.
Spring plate of the clutch or the
teeth on the gear ring are
broken.
Bowl or agitator are deformed.
Remedy
Check the house fuse,
power supply, power
plug.
Turn
the
handwheel
until
the
bowl
moved up.
Close the protective
grille.
Switch off the machine
and operate the gear
lever.
Check house security
fuse.
Allow the device to cool
down and restart after
cooling.
Disconnect from the
mains plug and turn the
drive shaft by hand.
Choose another gear.
Close the protective
grille.
Turn the handwheel
until the bowl has
moved up.
Replace seal.
Clean the guide and
grease it.
Fill gearbox with
lubricant.
Change transmission
block.
Change the spring plate
or the toothed ring.
Align the bowl or
agitator.
has
7