Electrical Grounding Instructions - JENN-AIR JGC8430 Manual De Instalación

Ocultar thumbs Ver también para JGC8430:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

ELECTRICAL WIRING INFORMATION
This appliance is equipped with a grounded type power cord. A grounded
outlet must be provided. It is recommended, for convenience, the outlet be
located (with reference to figure 6) as in A or B, below:
A. If no other appliance is to be installed below this appliance: within either
the shaded area or the cross hatched area shown in figure 6.
B. If a Model JJW8530, JJW9530, W27100X, W30400P or W132X electric
oven is to be installed below this appliance, either:
1. within the cross hatched area of figure 6, or,
2. within an adjacent cabinet.
If a wall oven is to be installed below this appliance and the counter unit's
outlet is to be mounted within the cross hatched area of figure 6:
1. The cabinet's lower front panel, below the oven, must be made
removable for access to the outlet.
2. A clearance hole for the power cord's plug (1-1/4² (3.18 cm) dia is
recommended) must be provided through the oven's floor support shelf
and, if necessary, through the slats supporting the shelf. The clearance
hole should be located as near as practical to the rear of the shelf.
3. When model JJW8530, JJW9530, W27100X, W30400P or W132X are
mounted below this appliance, and if the power outlet for this appliance
is to be located in the cross hatched area of figure 6, it is recommended
the power cord be routed through the external vertical clearance channel
at the left rear of the oven. The channel's cross section is approximately
4.2² x 2.25² (10.7 x 5.7 cm), extending the full height of the oven.
If the outlet is to be mounted in either a left or right adjacent cabinet, a
clearance hole, as described above, must be provided in the dividing wall
between the cabinets. Figure 4; page 4, illustrates a typical (left side)
dividing wall. The clearance hole (not shown in figure 4) can be located as
is convenient in this left wall or in the corresponding right wall.
In planning any installation, note that the free length of this appliance's
power cord, extending beyond a point 3-3/4² (9.53 cm) left of the nominal
center of the rear wall of the burner box, when viewed from the front of the
unit, is approximately 46² (117 cm).

ELECTRICAL GROUNDING INSTRUCTIONS

THIS APPLIANCE IS EQUIPPED WITH A THREE PRONG
GROUNDING PLUG FOR YOUR PROTECTION AGAINST SHOCK
HAZARD AND SHOULD BE PLUGGED DIRECTLY INTO A
PROPERLY GROUNDED RECEPTACLE. DO NOT CUT OR
REMOVE THE GROUNDING PRONG FROM THIS PLUG.
THIS APPLIANCE MUST BE DISCONNECTED FROM ITS
ELECTRICAL SUPPLY AT THE WALL RECEPTACLE BEFORE
SERVICING THE APPLIANCE.
User may experience occasional circuit tripping if Ground Fault Circuit
Interrupter (GFCI) outlet or breaker is in use.
FIGURE 6
6
WARNING
WARNING

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Jgc8645

Tabla de contenido