AC/DC current measurement
WARNING
shock, do not measure AC current on any circuit which voltage
exceeds 250 V~.
NOTICE
longer than 30 seconds. Exceeding 30 seconds may cause
damage to the product and/or the connector leads (O).
•
Insert the black connector lead (O) into the COM input jack
(G).
•
For current measurements of up to 4000 μA, set the
function switch (E) to the
connector lead (O) into the V/Ω/Temp/Hz/%/mA/μA input
jack (H).
•
For current measurements of up to 400 mA, set the function
switch (E) to the
lead (O) into the V/Ω/Temp/Hz/%/mA/μA input jack (H).
•
For current measurements of up to 10 A, set the function
switch (E) to the
lead (O) into the 10 A input jack (F).
•
Press the MODE button (D) to switch between AC and DC
mode. AC (12) or DC (13) lights up.
•
Switch off the power to the circuit under test. Break the
connection line/track and separate securely the 2 points
where the flow of current must be measured.
•
Connect in series by securely attaching each test probe (O)
at the 2 open points of the track/line.
•
Apply power to the circuit.
18
Risk of electric shock! To avoid electric
Do not make 10 A current measurements for
position and insert the red connector
position and insert the red connector
position and insert the red