Propane Supply; Ventilation; Installation - Factory Buys Direct FBDFA125V Manual Del Propietário

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Propane gas and propane tank(s) are to be
furnished by the user.
Use this heater only with a propane vapor
withdrawal supply system. See Chapter 5
of the Standard for Storage and Handling of
Liquefied Petroleum Gas, ANSI/NFPA 58 and/
or CAN/CGA B149.2. Your local library or fire
department will have this booklet.
The amount of propane gas ready for use
from propane tanks varies. Two factors decide
this amount:
1. The amount of propane gas in tank(s)
2. The temperature of tank(s)
WARNING: Follow the mini-
mum fresh, outside air ventila-
tion requirements. If proper
fresh, outside air ventilation is
not provided, carbon monoxide
poisoning can occur. Provide
proper fresh, outside air ventila-
tion before running heater.
WARNING: Review and un-
derstand the warnings in the
Safety, page 3. They are needed
to safely operate this heater. Fol-
low all local codes when using
this heater.
WARNING: Test all gas piping
and connections for leaks after
installation or servicing. Never
use an open flame to check for
a leak. Apply a noncorrosive
leak detection fluid to all joints.
Bubbles forming show a leak.
Correct all leaks at once.
1. Provide propane supply system (see

Propane Supply).

6
PROPANE SUPPLY
The chart below shows the number of 100 lb
(45 kg) tanks needed to run this heater.
20° F (-7° C) to -0° F (-18° C)
Less gas is vaporized at lower temperatures.
You may need a larger tank in colder weather.
Your local propane gas dealer will help you
select the proper supply system.

VENTILATION

air opening of at least a 3 ft
(0.91 m
Hr (105,500 k/j) rating. Provide
extra fresh air if more heaters
are being used.

INSTALLATION

2. Connect POL fitting on hose/regulator
Propane Supply
Valve
Propane
Tank
www.factorybuysdirect.com
Average Temp
At Tank Location
Above 20° F (-7° C)
WARNING: Provide a fresh
) for each 100,000 Btu/
2
assembly to propane tank(s). Turn POL
fitting counterclockwise into threads on
tank. Tighten firmly using wrench.
IMPORTANT: Position regulator so that
hose leaving the regulator is in a hori-
zontal position (see Figure 4). This places
the regulator vent in the proper position to
protect it from the weather.
Figure 4 - Regulator Position
No. Of Tanks
100 lb (45 kg)
2
3
2
Hose
Regulator
POL
Fitting
200187-01A

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Fbdfa175v

Tabla de contenido