Functions of buttons (Continued)
D: ON button
E: OFF button
F: Operation lamp
G: MODE button
H: Temperature setting
buttons
I: FAN SPEED button
J: FLAP button
CZ-64ESMC2̲all.indb 5
CZ-64ESMC2̲all.indb 5
This button is for turning the selected air conditioner on.
This button is for turning the selected air conditioner off.
This lamp lights when the unit is turned on.
Use this button to select one of the following fi ve operations:
: Used to automatically set cooling or heating operation.
(AUTO)
Only for heat pump type
: Used for normal heating operation.
(HEAT)
Only for heat pump type
: Used for dehumidifying without changing the room temperature.
(DRY)
: Used for normal cooling operation.
(COOL)
: Used to run the fan only, without heating or cooling operation.
(FAN)
When the
indication is displayed, you cannot change the mode
NOTE
from
and
or
to
units once then select the mode again.
: Press this button to increase the temperature setting.
: Press this button to decrease the temperature setting.
(AUTO)
: The air conditioner automatically decides the fan speed.
(HI.)
: High fan speed.
(MED.)
: Medium fan speed.
(LO.)
: Low fan speed.
1. Use this button to set the airfl ow direction to a specifi c angle. The
airfl ow direction is displayed on the remote control unit.
Operation mode
(COOL) or
(DRY)
(HEAT) or
(FAN)
(AUTO)
Cooling mode:
Heating mode:
• In the cool mode and dry mode, when the fl aps are set in a
downward position, condensation may form and drip around
the vent.
• Do not move the fl ap with your hands.
This function is available only for models U1 and T1.
NOTE
2. Use this button to make the airfl ow direction sweep up and down
(
)
automatically.
Press this button several times until the (
the display.
This function is available only for models U1, K1 and T1.
NOTE
1) The fl ap setting can be performed only for units that have no remote
NOTE
controllers.
2) In the ALL or ZONE mode, no fl ap setting can be performed. If
necessary, you should select the GROUP mode and use the FLAP
button.
(temperature range: 17 to 27 °C)
(temperature range: 16 to 26 °C)
(temperature range: 18 to 30 °C)
(temperature range: 18 to 30 °C)
or
and . To change the mode, turn off all
Number of airfl ow direction settings
3
5
3
5
) symbol appears on
EN
5
2011/06/03 16:37:48
2011/06/03 16:37:48