Troubleshooting - Hozelock 7825 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 16
Problem
The pump does not
pump water and the
motor is not running
The pump supplies a
limited amount of
water or the pump
does not pump
water, and the
motor is running
The pump works
only intermittently
Water is leaking
from the outlet of
the pump

Troubleshooting

Possible Cause
No electricity
Plug inserted incorrectly
Circuit breaker is tripped
Blocked impeller
Damaged motor
Pump has overheated
Float switch is preventing
pump turning on
Pump full of air
Obstructed inlet
Obstructed pipe/outlet
Worn impeller
Solid particles prevent the
free rotation of the impeller
The temperature of the fluid
is too high
Faulty motor
Inlet assembly not tight
enough
Remedy
Check that the electricity supply is turned
on and that the pump is correctly plugged
in
Reset electricity supply.
If the circuit breaker trips once more
contact a specialised electrician
Unplug from the electricity supply and
remove possible obstructions from the
impeller (Figs 8 & 9)
Contact Hozelock customer services for
assistance
Pump contains thermal protection - check
if pump case is hot, and if so, allow to
cool
The pump will only work when the float
switch is in the upright position, ensure
that is is able to reach the vertical
position
Unplug from the electricity supply and
disconnect outlet hose, submerge in
water and allow air to escape, re-connect
hose and power
Follow cleaning instructions detailed in
maintenance section (Figs 8 &9)
Remove obstructions in inlet hose or kinks
and clean out filter
Contact Hozelock customer services for
assistance
Clean inlet and impeller
(Figs 8 & 9)
Only use with fluids below 35ºC
Contact Hozelock customer services for
assistance
Tighten