Pict. 4: DC Runner Controller
Art.-No.
Pict.-No.
100.300
Pict. 4
5. Maintenance / Cleaning
From time to time, the pump needs to be cleaned. For cleaning, do the following:
First of all, remove the bottom plate. Then, turn the basket and take it off the pump. Now, the
complete impeller can be taken out.
When assembling, make sure that the ceramic shaft of the impeller goes into the socket of the
respective bearing.
6. Failures
The pump is designed to have a low maintenance requirement and under normal conditions will be
very reliable, provided it is protected from contamination. If the pump gets noisy, the suction basket
and the propeller need to be cleaned or the impeller and bearings need to be replaced.
7. Warranty
Should any defect in material or workmanship be found within 12 months of the date of purchase AB
Aqua Medic GmbH undertakes to repair or, at our option, replace the defective part free of charge –
always provided the product has been installed correctly, is used for the purpose that was intended
by us, is used in accordance with the operating instructions and is returned to us carriage paid. The
warranty term is not applicable on all consumable products.
Proof of Purchase is required by presentation of an original invoice or receipt indicating the dealer's
name, the model number and date of purchase, or a Guarantee Card if appropriate. This warranty
may not apply if any model or production number has been altered, deleted or removed,
unauthorised persons or organisations have executed repairs, modifications or alterations, or damage
is caused by accident, misuse or neglect. We regret we are unable to accept any liability for any
consequential loss. Please note that the product is not defective under the terms of this warranty
where the product, or any of its component parts, was not originally designed and / or manufactured
for the market in which it is used. These statements do not affect your statutory rights as a customer.
If you have any questions your dealer cannot answer please contact us. We reserve the right to
modify and adjust the specification of our products without prior notification.
AB Aqua Medic GmbH - Gewerbepark 24 - 49143 Bissendorf/Germany
10
Article
DC Runner Controller
It can be cleaned under running water and then be
- Technical changes reserved - 05/2015
re-assembled.