Genesis
®
Quick Release Nose Equipment
To P r e p a r e B a s e To o l t o A c c e p t Q u i c k R e l e a s e N o s e E q u i p m e n t
(Refer to the relevant Genesis
For nG3/4, G3/4 and G2/G2s tools remove Jaw Spreader Housing 71210-02101.
For nG1, nG2 and nG2s tools remove 'T' Adaptor 71213-02020.
Replace above part with 'T' Adaptor (item 6). Note: For nG3/4 tools 'T' Adaptor (item 6) is assembled through Nose Case Adaptor
Assembly (items 2, 3, 4, 5 and 8).
Screw the Nose Case Adaptor Assembly (items 2, 3, 4, 5 and 8) into the front of the tool.
The Nose Equipment Cartridge (item 9) is assembled onto the 'T' Adaptor (item 6) by sliding in a plane normal to the Piston.
Push the Quick Release Nose Casing (item 7) into the Nose Case Adaptor (item 5) ensuring flats are aligned, this locks the Quick
Release Nose Casing into position.
To R e m o v e t h e Q u i c k R e l e a s e N o s e E q u i p m e n t
Rotate the Quick Release Nose Casing (item 7) through 90 degrees and pull out of the Nose Case Adaptor (item 5).
To release the Nose Equipment Cartridge (item 9) from 'T' Adaptor (item 6) slide cartridge in a plane normal to the head Piston.
QUICK RELEASE NOSE CASING (7)
Item numbers in bold refer to the Parts List on the front page.
®
Tool Instruction Manual.)
ALIGNED SPANNER FLATS (LOCKED POSITION)
NOSE CASE ADAPTOR (5)