MT Tether Assembly
Conjunto MT
OptiTip Connector
OptiTip Conector
Coupling nut
Tuerca
Mate assemblies.
Junte los conjuntos.
Coupling nut
Tuerca
Align arrow on connector
tang with notch in
adapter.
Alinear la flecha de la
ceja del conector
con la ranura
del adaptador.
Connectorized
Drop Cable
Protective Cap
Conexión de la
acometida al
adaptador
OptiTap
Corning Optical Communications LLC • PO Box 489 • Hickory, NC 28603-0489 USA
800-743-2675 • FAX 828-325-5060 • International +1-828-901-5000 • www.corning.com/opcomm
Corning Optical Communications reserves the right to improve, enhance, and modify the features and specifications of Corning Optical Communications products without
prior notification. A complete listing of the trademarks of Corning Optical Communications is available at www.corning.com/opcomm/trademarks. All other trademarks are the
properties of their respective owners. Corning Optical Communications is ISO 9001 certified. © 2008, 2010, 2012, 2014 Corning Optical Communications. All rights reserved.
published in Mexico.
STANDARD RECOMMENDED PROCEDURE 206-338-QSG | ISSUE 6 | AprIl 2014 | PAGE 4 OF 4
Mate Terminal's OptiTip Connector
to FlexNAP™ Distribution Cable
or to OptiTip Adapter on another
Terminal
locate the appropriate tether
assembly or adapter. remove the dust
cap by turning in a counterclockwise
direction.
Tether dust cap
Cubre polvo
Hold the dust cap with one hand and
turn the coupling nut, NOT the dust
cap, to remove the dust cap from the
Dust cap
Cubre polvo
OptiTip™ connector.
Clean the connector and adapter
using the instructions provided with
theOptiTip MT Connector Cleaning
Tool (p/n TKT-OTMT-CMN-002).
Align the reference keys. Mate the two
assemblies and press together to fully
seat the sealing o-ring; then turn the
coupling nut in a clockwise direction.
KPA-2505
Mate OptiTap Connector to OptiTap
Adapter
Clean adapters and connectors per
the instructions provided with the
Optical Access Connector Cleaning
Kit.
Insert drop cable into OptiTap adapter.
Orient arrow on connector with notch
in adapter.
Screw drop cable hardware into
OptiTap adapter. Connector should
be installed hand tight. Do not over-
tighten.
Screw the plug into the cap. repeat
this section for all drop cables.
KPA-1461-EN_ES
Conexión del terminal Multipuerto
con Adaptador OptiTip al Cable de
Distribución o Adaptador OptiTip
de una otra Terminal
Localice el conjunto MT o adaptador
apropiado. Quite el cubre polvo
girándolo a la izquierda.
Sujete el cubre polvo con una mano y
gire la tuerca, NO el cubre polvo, para
quitar el tapón del conector OptiTip™.
limpie los adaptadores y conectores
según las instrucciones proveídas
con el Kit de limpieza del Conector de
OptiTip MT..
Alinee las guías de referencia y une
los conjuntos girando la tuerca a la
derecha.
Conexión del Conector OptiTap
con Adaptador OptiTap
limpie los adaptadores y conectores
según las instrucciones proveídas
con el Kit de limpieza del Conector de
Acceso Óptico.
Inserte la acometida en el adaptador
OptiTap. Alinee la flecha en el conector
hacia la ranura del adaptador.
Atornille el hardware de la acometida
conectorizada en el adaptador
OptiTap. Conector debe de
serinstalado a mano.
Atornille el tapón del adaptador
OptiTap en el tapón protector de la
acometida. repita esta sección para
todos las acometidas.