INSTRUCTION FOR USE

ADJUSTING THE BALANCE OF SQUEEGEE

Install the squeegee and tighten up the nuts (H
1.
connect the vacuum hose (G) to the squeegee.
Adjust the squeegee by squeegee adjusting handle (A, Figure
2.
11).
If there is gap between the ground and middle section of rear
a)
squeegee blade (B), adjust the knob (A) in counterclockwise
direction (F) until all sections of the rear squeegee blade make
good contact with the ground, the front blade touches the ground
slightly.
If there is gap between the ground and both end section of rear
b)
blade (C and D), adjust the knob (A) in clockwise direction (E)
until all sections of the rear squeegee blade make good contact
with the ground, the front blade touches the ground slightly.

FILLING SOLUTION TANK

Open the water inlet cover (B, Figure 12).
1.
Fill with water or solution suitable for work performance through
2.
the water inlet with filter.
The solution temperature must not exceed +104F (+40° C).
Do not overfill the tank, refer to water level indicator (H) for the
3.
water volume.
WARNING!
Use only low-foam and non-flammable detergents,
intended for automatic scrubber applications.

MACHINE START AND STOP

Starting the machine

Prepare the machine as shown in the previous paragraph.
1.
Insert the ignition key (A, Figure 13) and turn it to "I". Check Batteries status from display screen. If necessary charge the batteries
2.
(see the procedure in Maintenance chapter).
Drive the machine to the working area:
3.
By pushing either safety switch (F) to move forward or pressing the safety switch (F) together with the reverse switch (G) to move
backward. The forward speed can be adjusted with the adjuster (H).
Lower the squeegee (I) with the Squeegee lifting/lowering handle (J).
4.
Lower the brush/pad-holder deck (K) by pressing the one button start (L)
5.
Press the solution flow control buttons (O) as necessary, depending on the type of cleaning to be performed.
6.
Start cleaning:
7.
Press either safety switch (F) to activate the machine drive. If necessary, the forward speed can be adjusted with the adjuster (H).