ADVANCED OPERATION
The following Advanced Operation parameters require that you have an advanced controller. Basic remotes do not
have this capability.
All On/All Off
Depending upon your primary controller, the 39337 Plug-in module can be set to respond to ALL ON and ALL OFF
commands in up to four different ways. Some controllers may not be able to change the response from its default
setting. Please refer to your controller's instructions for information on whether or not it supports the
configuration function and if so, how to change this setting.
LED Light
When shipped from the factory, the LED is set to turn ON when the connected light is turned OFF. This is the
default setting and can be changed if your primary controller supports the node configuration function. To make
the LED turn ON when the light is turned ON, change parameter 3's value to "1". To turn the LED OFF at all
times, change parameter 3's value to 2.
• Parameter No: 3
• Length: 1 Byte
• Valid Values = 0, 1 or 2 (default 0)
Manual Reset (Factory Default) Instructions
1. Press and hold the top button while you plug the device into AC power, continue holding for at
least 3 seconds.
Association Statement
• This device supports Association Command Class (3 Groups)
• Association Group 1 supports Lifeline, Binary Switch Report
• Association Group 2 supports Basic Set and is controlled with the local load
• Association Group 3 supports Basic Set and is controlled by double pressing the On or Off button
• Each Association Group supports 5 total nodes