INSTALLATION
Pick a location which will allow you to blow the cold
air into the area you want. Windows used for
installation must be strong enough to support the
weight of the air conditioner.
Good installation with
special attention to the proper position of the unit
will lessen the chance that service will be needed.
When cooling more than one room, installation
location is very important. To cool your rooms, cold
air must be blown from the air conditioner in a
straight path.
HOW TO INSTALL
If the air conditioner
is blocked
by a storm
window
frame, see step 16 on page 8 before
beginning
to install.
H
Remove the screws which fasten the cabinet at
the back and side of the unit. Save side screws.
Discard back screws.
'
/..
FIG. 3
I_'_ Slide the unit out of the cabinet by gripping the
base pan handle and pull forward while bracing the
cabinet.
FIG. 4
I_'! Cut the FOAM SEAL (ITEM J) to fit the
underside of the window sash. Peel off the backing
and attach the FOAM SEAL as shown in Fig. 5.
I_1 Insert the side curtain (ITEM A) into the upper guide
and lower guide of the air conditioner. Fasten the curtains
to the unit with screws (ITEM E).
Lower Guide_
_
ITEME
FIG. 6
_Open
the window. Mark a line on the center of the
window inner sill. Loosely attach the sill bracket (ITEM C)
to the support bracket (ITEM B) using the carriage bolt
(ITEM I) and the lock nut (ITEM D).
ITEM
ITEM I
r'_
Attach the sill bracket to the window sill using the
screws (ITEM F). Carefully place the cabinet on the
window inner sill and align the center of the cabinet
front with the center line marked on the window inner
sill.
/Machine screw
Cabinet_
/and locknut
trackhole
,Outer
/edge of
ITEM
windowsill
,
/
Carriagebolt...............
"
andlocknut
Sillbracket
FIG. 8
H
Using the M-screw (ITEM H) and the lock nut
(ITEM D), attach the support bracket to the cabinet
track hole. Use the first track hole after the sill bracket
on the outer edge of the window sill. Tighten the
carriage bolt and the lock nut. Be sure the cabinet
slants downward 1/4" from level.
CAUTION: Do not drill a hole in the bottom pan. The
unit is designed to operate with approximately 1/2" of
water in bottom pan.
z
Sash
FIG. 5
Lowerguide
INDOOR
Cabinet
OUTDOOR
FIG. 9
-6-