2
Installation
The proper location
• Install your machine in environments which
have no risk of freezing and in a stable and
level position.
• Do not place your machine on a long pile rug
or on similar surfaces.
• Operate your machine in a well ventilated,
dust-free environment.
B
Make sure that your machine is not placed
on the power cable.
B
Place it at least 3 cm away from the edges
of other furniture and the walls.
• A special part (Part no: 295 970 0100)
replacing the top trim must be provided and
installed by the Authorized Service in order
to use the machine under a counter or in
a cupboard. It should never be operated
without the top trim.
• Place the machine on a sound floor. If it is to
be placed on top of a washing machine, the
approximate weight together may reach 180
kg when they are full.
• A fitting device should be used between the
two machines for use on a washing machine.
The fitting device (Part no 296 280 0100
white/ 296 280 0200 grey ) must be installed
by the Authorized Service.
Levelling
In order to ensure that your
machine operates more silently
and vibration-free, it must stand
level and balanced on its feet.
Front feet of your machine
can be adjusted. Balance the
machine by adjusting the feet.
Loosen the feet by hand. Adjust them until the
machine stands level and firm.
C
Never unscrew the adjustable feet from their
housings.
2 plastic pieces supplied together with the
Operating Instructions prevent your machine
from slipping on wet and slippery surfaces.
Tilt your machine to backwards t install these
plastic parts. Fit the plastic parts to the front
adjustable feet. Press on the plastic parts to fix
them in their places. Check the balance of your
machine again and readjust the adjustable feet
if necessary.
Ventilation hose and connection (for
products equipped with an outlet vent)
Ventilation hose assures exhausting of the air
from inside the machine. Vented dryer has 1 air
outlet. Stainless sheet metal or aluminum pipes
can be used instead of the hose. The diameter
of the pipe to be used should be minimum 10
cm.
Maximum hose and pipe lengths are given in
the table below.
Maximum length
1 elbow 45°
1 elbow 90°
1 elbow 90° short
1 wall passage
Each elbow and other passages should be
subtracted from the above maximum length.
Connect the air outlet hose to the hose spacer
piece by turning it anti-clockwise in order to
connect the ventilation hose. Make the hose
passages as shown below.
C
Exhaust of humid air from the dryer into the
room is inconvenient. Air outlet hose must
be extended directly to the outdoors. There
must be a small number of elbows as not to
hinder air ventilation.
C
The ventilation hose can be routed outdoors
via a window or it can be connected to the
air outlet in the bathroom.
C
To prevent water accumulation in the hose,
make sure that it is not folded on the floor.
A
The air ventilation hose should not be
connected to the chimney of a stove or a
fireplace.
A
Pay attention that the air inlet openings are
unobstructed.
A
Do not operate your machine at the same
time with heaters such as a coal or gas
stove. Airflow may cause the chimney to flare
up. Airflow may cause the chimney to flame
up.
Connection to a water drain (for
products equipped with a condenser)
In products equipped with a condenser unit
the water accumulated during the drying cycle
is collected in the water tank. You should drain
the accumulated water after each washing
cycle.
5 - EN
Hose
Pipe
4 m
5 m
-1.0 m
-0.3 m
-1.8 m
-0.6 m
-2.7 m
-2.0 m
-2.0 m

Publicidad