INSTALLATION
For easy installation, select an existing light with a wall
switch for replacement.
For best performance, locate the fi xture about 8 ft. (2.4 m)
above the ground.
CAUTION: The sensor must be mounted below the
lamp housing for wall installations.
❒ Drill out the holes if needed
to mount the backplate to the
junction box.
CAUTION to avoid fi re or burn hazards:
• Allow fi xture to cool before touching. The bulb
and fi xture operate at high temperatures.
• Keep fi xture at least 2" (5 cm) from combustible
materials. Do not aim at objects closer than 3 feet
(1 m).
• Re-lamp with type T 150W (or less) halogen 120
VAC lamp only.
For under eave installation, the sensor head must
be rotated as shown in the next two steps for proper
operation and to avoid the risk of electrical shock.
❒
Rotate the sensor head to-
wards the clamp screw joint.
Clamp Screw
❒
Then rotate the sensor
head counterclockwise
180° so the controls face
down.
Controls
If the sensor pops out of the ball joint, loosen the
clamp screw and push the sensor back into the ball
joint. Tighten the clamp screw when done.
B
I
ULB
NSTALLATION AND
❒ When relamping, turn power off and let the fi xture
cool.
❒ Remove the screw that holds the glass cover shut.
Remove the old bulb by pushing the bulb towards
the right until the left side of the bulb is clear of the
left socket.
❒ To insert the new bulb, push the bulb into the right
❒ Check that the bulb is seated properly.
❒ Close the glass cover. Replace screw.
or fuse.
❒ Remove the existing light fi xture.
❒ Strip about 5/8" insulation from the existing junction
❒ Route the Light Control's wires through the large
❒ Twist the junction box wires and fi xture wires together
Black to Black
Controls
Junction box ground wire to
green ground wire on fi xture.
❒ Align the Light Control cover plate and cover plate
❒ If not installed on a weatherproof box or if an adaptor
R
ELAMPING
2
socket so the bulb fi ts completely into the left
socket.
W
L
IRE THE
IGHT
WARNING: Turn power off at circuit breaker
box wiring.
hole in the gasket.
as shown. Secure with wire connectors.
White to White
M
L
OUNT THE
IGHT
gasket and the junction box. Insert and tighten the
mounting screws.
plate is used, caulk the wall plate and mounting
surface with silicone weather sealant.
RIGHT
The halogen light must be
mounted horizontally (+/- 4°).
C
ONTROL
Cover Plate
Gasket
C
ONTROL
WRONG
598-1310-00