6
stand 15.12.09
suitable for indoor and outdoor use. wind
sensitivity varies when the slides are adju-
sted or removed. when kept outdoors please
remove the combustion chamber and store in
a dry place.
remove all packaging materials.
remove all infl ammable elements from the
chamber.
place the combustion sponge in the combu-
stion chamber.
place the extinguisher sliding gauges on the
combustion chamber. the extinguisher slide
without the holes should be facing away from
you.
put the combustion chamber in the HOME
FLAME. please ensure that you turn the
combustion chamber with the max. mar-
king towards you. select a suitable position.
HOME FLAME must not be operated on heat-
sensitive or
infl ammable surfaces. impor-
tant: please allow the minimum distance of 2
meters from infl ammable objects. there must
be a distance of at least 1.80 meter between
HOME FLAME and the ceiling.
insert the panels carefully into the specially
provided slits. remove one on the small pa-
nels before fi lling the combustion chamber.
7
the fi replace comes with a spout that fi ts on
all RADIUS DESIGN bioethanol cans, and you
should keep it.
8
make sure that no foils, packaging or other
combustible materials are in the combustion
chamber. remove the extinguisher slide and
fi ll the combustion chamber with max. 1.7
l bioethanol (max. marking). make sure that
no fuel is spilt next to the combustion cham-
ber. the ceramic sponge must not be covered
with ethanol. Only use RADIUS DESIGN fuel
(artic.-nr. 536 3l / 536 5l or 536 10l), do not
9
throw any combustible items or liquids into
the combustion chamber. when the tank le-
vel is low wait 10 minutes after fi lling before
lighting to allow the ceramic sponge to ab-
sorb ethanol. never put fuel into the sponge
when it is hot or during operation. before it
is put into operation again the burner must
have cooled down. allow at least one hour for
this. before recommisioning, the combustion
chamber needs to be refi lled until the max.
marking is reached.
10
only use long pieces of fi rewood (min. 20
cm) or long fi replace lighters (min. 20 cm) to
light the combustion chamber. there is a dan-
ger of explosion. should the burner not work
after three attempts to light it please close
the extinguisher sliding gauges and wait 2
minutes before attempting to light it again.
11
never light the combustion chamber from
above, but only from the side. keep at a safe
distance and remember that there may be a
slight explosion or tongue of fl ame!
12

Publicidad