Trac Electrical Feeds
For electrical feed from above utilizing a floating
electrical feed.
1. Make sure the power is OFF!
2. Fasten mounting strap and ground clip assembly to outlet box.
Connect ground wire.
3. Locate Trac below outlet box in desired position, then:
a) Rotate ground clip to accept Trac and push Trac into clip.
b) Fasten Trac to ceiling following instructions supplied with the
Trac section.
c) Trac ends must be terminated with either a dead end or
a connector.
4. Insert electrical adapter into Trac – rotate 90° to locked position
to make electrical contact.
a) Arrow on the electrical adapter must point to the Trac polarity
line when correctly installed.
b) Center line of electrical adapter must be set on center line of
outlet box.
5. Fasten positive wire to screw terminal marked "P" for single
circuit Trac or to screw terminal marked "P
(TU series). For two circuit Trac only, fasten the second positive
wire to screw terminal marked "P
".
2
6. Fasten white wire (neutral) to screw terminal marked "N".
7. Push excess wire back into outlet box – wire must hug Trac
side. Install cover and secure with screw.
Trac Connectors
Mini Straight Connector
Joins 2 Trac sections end to end.
"T" Connector
Joins 3 Trac sections. To rotate polarity configuration, remove
cover. Rotate legs to new polarity position and replace cover.
To reverse polarity, use the reverse polarity configuration.
"X" Connector
Joins 4 Trac sections at 90° angles.
Adjustable Connector
Joins 2 Trac sections to make a 90° angle or straight run. Is
factory assembled to make a 90° turn. If opposite angle or straight
connection is required, cover must be removed... the connector
then rotated to new position and cover replaced. Both a right angle
and straight cover are supplied.
Flexible Connector
For inside and outside corners and for other than 90° angles.
To attach the connectors:
1. Make sure the power is OFF!
2. Insert connector fully into Trac with arrow pointing toward Trac
polarity line. Secure with set screw.
3. Attach Trac to ceiling following instructions supplied with the
Trac section.
1300 South Wolf Road • Des Plaines, IL 60018 • Phone 800-323-5068 • www.junolightinggroup.com

INSTALLATION INSTRUCTIONS

Juno T, TU, R and V series Trac connectors
" for two circuit Trac
1
Ground Clip
Dead End
Electrical
Adapter
Mini-Straight
Connector
"T" Connector
"X" Connector
Adjustable Connector
Flexible Connector
©2016 Acuity Brands Lighting, Inc.
Mounting Strap
Trac Polarity Line
Polarity Arrow
(must point to Trac
Polarity Line)
Standard
Reverse Polarity
"T" Connector
"T" Connector
Factory Wiring
Angle Left
Angle Right
Straight
Rev 2/16