Descargar Imprimir esta página

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

Programming
Panel (See
owner's manual)
NEXT
PROGRAM
PGM
PGM
BACK
MANUAL ZONE
MANUAL TEST
MANUAL
Hinged Wiring
PROGRAM
Compartment
MULTIMETER
Door
VALVE
LOCATOR
SENSOR
OPERATION
RUN AND SOAK
CYCLES
Fuse
ADVANCED FUNCTIONS
FUSE STATUS LIGHT
LA LUZ ESTADO FUSIBLE
GREEN: GOOD FUSE
VERDE: FUSIBLE BUENO
RED: BLOWN FUSE
ROJO: FUSIBLE MALO
NO LIGHT: NO POWER
NO LUZ: NO ELECTRICIDAD
S1
24V Auxiliary
Power Connections
Hot Post
Sensor Connections
Common Wire Connection
Master Valve/Pump Connection
Controller Installation
The PL800 is designed for indoor installations only. Choose a location that
is convenient to valve wiring and a 120V (230V for export models E-PL800
and E-PL800A) outlet. The PL800 is not intended for operation by children
and should be installed in a location convenient for operation by adults
but out of the reach of children. Choose a location with good lighting to
maximize display readability.
Mounting the PL800 Controller
1.
Install a wall anchor. Insert the provided mounting screw into the the
wall anchor to a depth allowing the head of the screw to be inserted in
the keyhole at the top center of the housing. The housing should be flat
against the wall with the head of the screw in the keyhole.
2.
Remove the hinged wiring compartment door and set it aside
temporarily.
1.
Level the controller housing on the wall and secure it with a second
screw through the center housing standoff located just below the
terminal position for Zone 1. If additional screws are desired, use the
left and right standoffs at the bottom of the housing.
24V Valve Wiring
1.
Connect Common Valve Wire to COM screw.
2.
Connect optional master valve or pump start to MV-P terminal and the
Common terminal.
3.
Connect zones 1 through 4 to terminal screws provided. Note: You
should always locate zones by using the Hot Post connection. On the
PL800, you may use the left 24V auxiliary terminal position as a Hot
Post. This terminal position is protected by the fuse.
4.
If you require constant 24VAC power for a wireless sensor or other
optional powered equipment, use the two 24VAC auxiliary terminals
provided at the left end of the terminal strip.
MANUAL PROGRAM
PRESS TO START
SUN
MON
TUE WED
THU
FRI SAT
PGM
A
ADJUST VALUE
B
C
D
FAULT
NO AC
ZONE START
RUN
SYSTEM OFF
CURRENT
TIME/DATE
PROGRAM
ENGLISH
START TIMES
LANGUAGE
SPANISH
ZONE RUN
TIMES
ACTIVE
SENSOR
DAYS TO
BYPASS
WATER
OMIT TIMES/
DAYS
MONTHLY % ADJUST
S2 COM MV/P
2
3
4
5
6
7
Conduit
Connections
Skirt for
for expansion
24V AC
modules (SLM2)
Wiring
Terminals for zones 1 through 4
PL800 Controller
Installation Instructions
Wall mounting keyhole
24V AC Connection
24V AC Cable
Restraints
Additional wall mounting
SLHUB
screw locations (optional).
Compartment
24V AC Power Wiring
Insert male connector into female receptacle on the side of the PL800
housing. Use provided restraints to route the power cable down the side of
the housing. Plug transformer into convenient outlet.
Adding Extra Zones
Connections for two SLM2 modules are provided at the right side of the
terminal strip to expand the PL800 to 6 or 8 zones. The SLM2 modules are
hot swappable and the PL800 will instantly recognize the additional zones.
Push each module onto the male connector. Use the provided terminal
screws to secure the front of the module. Do not skip module position 5
and 6. Always install that module position first. To remove an SLM2 module,
first remove the terminal screws and then use a small flat blade screwdriver
to move the module forward from the rear connector.
Connecting a Sensor
Use the S1 and S2 positions on the terminal strip for connecting a standard
type rain sense or freeze sense. Discard the wire loop if a sensor is
connected. Important: The wire loop must be left in place if a sensor is not
in use.
Conduit Skirt
Complete your installation by sliding the conduit skirt into the locking slots
on the housing. Use two additional provided screws to secure the bottom
of the skirt to the wall.
Replace the hinged wiring compartment door.
Electrical Data for the PL800.
The PL800 uses a 750mA transformer to power a total of 2 valves including
a master valve or pump start relay. Take caution when installing a pump
relay that maximum output current does not exceed 720mA.
The PL800 does not use a backup battery. All programming information
including time and date are non-volatile.
Replacement fuse for the PL800 is a 1.0A, 3AG, slow blow fuse.
Monday – Friday 8:00 am – 5:00 pm CST
www.weathermatic.com
Restraint for SLW
communication cable
Help Desk: 888-484-3776
Online: support.weathermatic.com
Email: support@weathermatic.com
ADPL800_revB
1

Publicidad

loading

Resumen de contenidos para Proline PL800

  • Página 1 120V (230V for export models E-PL800 terminal strip to expand the PL800 to 6 or 8 zones. The SLM2 modules are and E-PL800A) outlet. The PL800 is not intended for operation by children hot swappable and the PL800 will instantly recognize the additional zones.
  • Página 2 El fusible de repuesto para el PL800 es un fusible 1.0A, 3AG, de acción auxiliares de 24V AC situadas en el extremo izquierdo de la lámina de retardada.