ENGLISH
INSTALLATION
•
Remove the door phone hood.
•
Fix the base to the wall with the screws and bolts included.
•
Confi gure the programming switches and make the connections.
•
Refi t the hood.
DESCRIPTION OF TERMINALS
}
Line
Bus line in
Line
}
CP
Floor call
CP
}
S+
Supplementary ringer
S-
10
CONFIGURATION
Default settings: default indoor station settings are:
USER= 127
INDOOR STATION= 0
The dip switches must always be arranged in the correct setting for correct operation of the system in
this case.
§
Refer to the system booklet provided with the power unit 1083/20 for dip switch settings.
CODE: user code.
Set a number from 0 to 127 according to the following rules:
•
No two apartments in the system can have the same user code.
•
Indoor stations in parallel in the same apartment must have the same user code.
•
User codes be consecutive in the same column must.
§
Use the CODE dip switches from 2 to 8 (2= most signifi cant bit - 8= least signifi cant bit) to set the
required code. Dip switch 1 must be OFF.
INT:
apartment station code.
Set a number from 0 to 3 according to the following rules:
•
The indoor station code must be 0 if there is only one station in the apartment.
•
Up to 4 apartment stations can be connected in parallel using the same user code and different indoor
station codes.
The indoor station code is used to identify the single stations of the same user. This means that intercom
calls can be address to the single user in the same apartment. All the users indoor stations will ring at the
same time in the event of intercom calls to different apartments, door unit calls and fl oor calls. Extension 0
rings immediately when a call is received. Extensions 1, 2 and 3 will ring in sequence after each other.
DS1183-004A
DS1183-004A
ON
OFF
O N
O N
=
=
11