Application; Connecting To Cs-300 Shank; Safety Precautions - Nippon Gases CS-300 / H-402 CE-1 Intrucciones De Manejo Y Seguridad

Lanza para calentamiento
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

1. APPLICATION

The CS-300 / H-402 CE-1 NIPPON GASES attachment for heating is designed to be connected to
NIPPON GASES CS-300 shank (Cod. 230.2005) or NIPPON GASES H-402 (Cod. 2302042) for use in
heating applications with Oxygen & Acetylene.

2. CONNECTING TO CS-300 SHANK

2.1. Insert the mixer of attachment on the frontal tube of the shank.
2.2. Turn heating attachment to have welding tip in comfortable position.
2.3. Screw & tighten with a wrench, without excessive strength, (tightness is made with an O-ring
& by metal/metal contact on the oxygen circuit).

3. SAFETY PRECAUTIONS

Before connecting the torch & during the whole operation, take care to follow these instructions.
In case of doubt, get in touch with NIPPON GASES.
3.1.
Only use genuine & appropriate accessories from NIPPON GASES (cutting nozzles &
spare parts).
3.2.
NEVER USE OIL OR GREASE with any component of the equipment.
OXYGEN WITH OIL AND GREASE: DANGER OF EXPLOSION.
3.3.
Do not set pressures that are really different from those recommended.
WRONG PRESSURES = DIFFICULT FLAME CONTROL & RISK OF GAS BACKFLOWING.
3.4. SET ASIDE:
Torches with gas escapes and/or too many crackers.
-
Damaged nozzles or tips.
-
Old hoses.
-
ESCAPES & OBSTRUCTIONS = DANGER OF GAS ACCUMULATION &/OR GAS BACKFLOWING.
3.5.
We recommend to always use non return valves
¡ PREFERENT WITH DIRECT CONNECTION TO THE TORCH !
3.6.
Do not use oxygen or fuel gases to clean parts with blowing system or to blow on human
body.
3.7.
Do not rub cutting nozzles on metallic parts or abrasive material to clean them; use
special accessory (broach) or rub on wood.