j. Once opened, the display shows the message "OPENEd".
9. OPENING WITH THE EMERGENCY KEY
a. Remove the emergency opening key cover to the right side of the keyboard.
b. Enter one of the two emergency keys supplied with the notch in the lock.
c. Turn the key clockwise.
d. When there is a sufficient voltage to the battery, the display shows the
message ''HELLO' followed by "OPENEd" and the safe is open.
e. To remove, you need to turn the key back to the start position - it is closed
again.
10. PROTOCOL FUNCTION
The safe model "VISION" is equipped with a simple protocol function.
To properly use the protocol function, we recommend that during safe commis-
sioning to set the current date and time.
The date is given in the format YYMMDD (Year - Month - Day).
The time is shown in the format HHMMSS (hour - minutes - seconds).
DATE / TIME PROGRAMMING
a. Tap the screen in the middle, the display shows "HELLO".
b. Press "*" twice.
c. The display shows "SUPER".
d. Enter the current master code (default 0-0-0-0-0-0).
e. Press "#" to confirm.
f. The display shows "CC --".
g. Enter "0 8".
h. Press "#" to confirm.
i. The display shows "SEt-dt".
j. Now enter the last two digits of the current year (eg. 17 for 2017), the
current month (i.e. May 5) and the current day.
k. Press "#" to confirm.
l. The display shows one hour of the system.
m. Enter the current time (in 24 hours format)
n. Press "#" to confirm.
o. The display shows "GOOD".
p. The date and time have been set.
q. The display shows "CC --".
r. To exit the menu, press the "*".
READING OPENING PROTOCOL
a. Tap the screen in the middle, the display shows "HELLO".
b. Press "*" twice.
c. The display shows "SUPER".
d. Enter the current master code (default 0-0-0-0-0-0).
e. Press "#" to confirm.
f. The display shows "CC --".
g. Enter "0 9" ein.
h. Press "#" to confirm.
i. The display shows the short message "rECOrd".
j. Indicate the last opening.
The protocol is displayed in the following format "YYMMDD" "SSMM - opening
type."
k. Key "6", indicating opening time and type.
l. Press "2" to indicate previous openings.
m. To exit the menu, press twice "*" key.
INFORMATION PROTOCOL
1 - Open with the master code.
8 - Open with the User Code.
9 - Open with the emergency key.
PROTOCOL EXAMPLE:
6
Vision.indd 6
Press "6" to indicate the time and type of opening.
NAVIGATING IN THE PROTOCOL MENU
6 - Indicating opening time and type.
2 - Indicating the previous opening.
4 - Indicating opening date.
8 - Indicating the next opening.
11. RESTORE ELECTRONIC LOCK TO FACTORY
SETTINGS
a. Remove the door trim panel.
b. Press "RESET" for five seconds.
c. After five seconds, the display shows "RESET".
d. Electronic lock is reset to factory settings.
- Date and time of the system time.
- Protocol Opening removed.
1701011212-1
- Master Code "0-0-0-0-0-0"
- User Code "1-6-8-0"
27.02.2017 13:21:47