TECHNICAL DATA

Input (supply) terminals:
Input rated voltage:
Input voltage tolerance:
Nominal frequency:
Nominal power consumption:
Number of operation modes:
Number of channels:
Transmission:
Transmission way:
Coding:
Maximum number of transmitters:
Range:
Time adjustment:
Optical signaling:
Receiver's output clamps:
Maximum output load:
Number of terminal clamps:
Section of connecting cables:
Ambient temperature range:
Operating position:
Casing mounting:
Casing protection degree:
Overvoltage category:
Pollution degree:
Surge voltage:
Dimensions:
Weight:
CAUTION: The given range concerns open area - an ideal condition without any natural or artificial obstacles.
If there are some obstacles between a transmitter and a receiver, it is advisable to decrease the range ac-
cording to: wood and plaster: from 5 to 20 %, bricks: from 10 to 40 %, reinforced concrete: from 40 to 80 %,
metal: from 90 to 100%, glass: from 10 to 20 %, Over- and underground medium and high electrical power
lines, radio and television transmitters, GSM transmitters set close to a device system have also a negative
influence on the range.
L, N
230 V AC
-15 ÷ +10 %
50 / 60 Hz
0,5 W
5
1
radio 868 MHz
unidirectional
addressing transmission
32
up to 230 m in the open area
1 sec ÷ 18 hours (every 1 sec.)
LED red diode
, N
250 W
4
up to 2,5 mm
2
-10 ÷ +55
C
o
free
installation cable box Ø60 mm
IP20
II
2
1 kV
47,5 x 47,5 x 20 mm
0,036 kg