3.
3.3 Watermark Verification Operation
Press the WM function button to turn the WM screen ON, the entire inspection area will
be illuminated to make bill's analysis procedure easier and faster. Proceed to verify the
watermark features embedded in the bill or document and confirm their authenticity. The
absence, displacement, or low quality of this feature will indicate the bill is not genuine.
The internal timer will keep the WM ON for about 30 sec., in case you require more time,
just press the WM button again.
3.4 Magnetic Verification Operation
Once the detector is turned ON, the magnetic circuitry is already active and remains so
while the unit is ON.
Proceed to rub the area of the bill that must contain magnetic ink against the magnetic
head. If the verification window flash in GREEN color and at the same time a BEEPING
sound is emitted, it confirms the Magnetic ink feature is present on the area just verified.
In case none of these signs are present, means there is not MG ink in the scanned area.
10