Lighting Instructions; Shut Down Instructions - Remington REM-18-PCH-O Manual Del Usuario E Instrucciones De Operación

Calentador de propano tipo gabinete
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Checking For Leaks
– To check for leaks, make up a 50/50 solution
of dish soap and water. Apply this solution
to all gas connections. If bubbles appear,
there is a leak. If a leak is found, turn off
the gas supply, and re-connect the leaking
connection. If the leak persists after several
tries, contact Pinnacle Customer Service at
866-676-1989.
– The installation of this heater must meet all
local codes and/or gas utility requirements. In
the absence of local codes, the National Fuel
Code ANSI Z223.1 should be followed.
– The minimum clearances to any combustible
construction materials must be maintained at
all times (See Page 2).
– Inspect the heater before each use, and at
least annually by a qualified service person.
Supply Valve
Regulator
Hose
Figure 6
WARNING
metal components while in operation. Keep
gasoline and any other flammable liquids
away from the heater.
© 2017, Pinnacle Climate Technologies, Inc.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING, CONNECTED
TO A POWER SOURCE, OR WHILE CONNECTED TO A FUEL SOURCE
Operation
Propane Tank
EXTREMELY HOT
during operation.
Do Not touch any

Lighting Instructions:

1. STOP! Read all of the safety information
provided with this heater.
2. Turn valve on propane cylinder
COUNTERCLOCKWISE until fully open.
3. Wait five (5) minutes for any gas to clear. Smell
for gas. If none is evident, proceed to the next
step.
4. Push in the valve knob and turn to "PILOT".
NOTE: If this is first time use for heater or LP
cylinder has been replaced, hold the valve knob for
approximately 30 seconds to allow bleeding of air
from system then turn valve knob to PILOT.
5. While depressing the valve knob, press
red piezo ignition button to ignite. It may be
necessary to press the igniter button several
times to ignite the center burner panel.
6. Continue to hold valve knob down for 30
seconds after the panel has lit. This will heat
the thermocouple. After 30 seconds, release
the valve knob.
7. If heater fails to light, or does not stay lit, repeat
steps 2 through 6.
8. When the center burner panel stays lit, turn the
valve knob to the desired setting.

Shut Down Instructions

1. Turn valve knob to the OFF position.
2. Turn the knob at the LP cylinder CLOCKWISE
to the OFF position.
3. Disconnect regulator hose assembly from the
LP cylinder.
6
Cabinet Heater User's Manual

Publicidad

Tabla de contenido
loading

Tabla de contenido