Assembly and Installation (continued)
3
Connecting the wires
WARNING: The wire connector (E) contacts have sharp edges for
piercing the main low voltage cable. To avoid injury, do not touch the
metal contacts.
CAUTION: The wire from the low voltage power unit should be 12-16
AWG type underground Low Energy Circuit Cable.
IMPORTANT:
Protect the wiring by routing it in close proximity to the light
□
fitting, or next to a building structure such as a house or a deck.
The landscape wire and connector can also be hidden under
□
stone or buried under grass at a maximum depth of 6 in. (15.24
cm).
Do not install the fixture within 10 ft. of a pool, spa, or fountain.
□
Do not submerge the fixture in water.
□
Place the wire connector (E) on opposite sides of the low voltage cable
□
(not included) from the transformer (not included) where the fixture will
be located.
Align and fit the main low voltage cable vertically to the slot of the wire
□
connector (E).
Press the wire connector (E) together until it is locked around the main
□
low voltage cable. The pre-set prongs will pierce the cable insulation and
establish contact with the electrical wire inside.
Once the wire connector (E) is in place, it is recommended to wrap it with
□
electrical tape (not included).
After all fixtures are installed, turn on the transformer.
□