Fault Finding.
Malfunction
Vacuum cleaner can-
not be switched on.
Reduced vacuuming
capacity.
Dust escapes during
vacuuming.
No suction capacity
when wet vacuuming.
Automatic shut-off
does not actuate.
maintenance. After the maintenance,
the maintenance area should be
cleaned.
Products that have come into contact
with asbestos may not be sent in for
repair. Dispose of products contam-
inated with asbestos according to the
applicable country-specific regula-
tions for such disposal.
The current spare parts list for this
vacuum cleaner can be viewed on
the Internet at www.fein.com.
If required, you can change the
following parts yourself:
Fleece filter bag, flat-fold filter, filter
cartridge, hose, tool sleeve
Cause
Circuit breaker of
power connection has
tripped.
Vacuum cleaner in
remote control opera-
tion.
Vacuum cleaner not fit-
ted correctly.
Vacuum system clogged. Clean vacuum hose and
Fleece filter bag full.
Flat-fold filter full.
Incorrect installation
position of flat-fold filter
Container full.
Sensors soiled/dirty.
Troubleshooting
Ensure power supply.
Set operating-mode
selector switch to "I".
Mount vacuum cleaner
lid properly and com-
pletely close both fasten-
ers.
extension tubes.
Replace fleece filter bag.
Replace flat-fold filter.
Correct installation posi-
tion of flat-fold filter.
Empty container.
Clean sensors and space
in between with a brush.