PANEL CONECTORS
Version
amplifi er
1 Door open' warning
language selection
Spanish
English
Greek
Polish
Danish
Icelandic
TECHNICAL FEATURES
PANEL
Power Supply
Consumption
in standby
audio active
illumination by pushbutton modules
Operating Temperature
Audio power from the apartment to the panel
Audio power from the panel to the apartment
Adjustable volume both ways
TELEPHONE
Power Supply
Consumption
in standby
audio active
Operating Temperature
6
VDS iLOFT AUDIO KIT
Dutch/
French
German
Flemish
Czech
Slovak
Turkish
Russian
Italian
Hindi
JP2: Main / Secondary Panel Selection
MASTER Panel Default:
SLAVE Panel
LED diagnostic
Blinking to indicate short-circuit between + and L upon
making a call from the panel.
Selecting the language 1
of the message "door open."
Audio Settings
of the Monitor, panel and open door.
Microphone Connection.
Panel Connectors:
+, - : power (18Vdc).
L : data bus.
C, NO, NC: Relay contact, 2A@30Vdc (lock-release connection)
+12: 12 Vdc (0,5A) output
BS, -: entrance hall button.
S : activation of the exchanger
Catalonian
Valencian
Balearic
Persian/
Chinese
Arabic
Farsi
Hungarian
Hebrew
[-10 , +60 °C] / [14 , +140 °F]
[-5, +40 ºC] / [23, +104 ºF]
Portuguese
Basque
Galician
Swedish
Norwegian
Finnish
bell
DEACTIVATED
18 Vdc
57 mA
210 mA
35 mA
2W
0,15 W
18 Vdc
24 mA
100 mA
Cod. 970027 V01_17